Evaluation of the Xpert HCV Viral Load point-of-care assay from venepuncture-collected and finger-stick capillary whole-blood samples: a cohort study.
نویسندگان
چکیده
BACKGROUND Point-of-care hepatitis C virus (HCV) RNA testing offers an advantage over antibody testing (which only indicates previous exposure), enabling diagnosis of active infection in a single visit. In this study, we evaluated the performance of the Xpert HCV Viral Load assay with venepuncture and finger-stick capillary whole-blood samples. METHODS Plasma and finger-stick capillary whole-blood samples were collected from participants in an observational cohort enrolled at five sites in Australia (three drug and alcohol clinics, one homelessness service, and one needle and syringe programme). We compared the sensitivity and specificity of the Xpert HCV Viral Load test for HCV RNA detection by venepuncture and finger-stick collection with the Abbott RealTime HCV Viral Load assay (gold standard). FINDINGS Of 210 participants enrolled between Feb 8, 2016, and July 27, 2016, 150 participants had viral load testing results for the three assays tested. HCV RNA was detected in 45 (30% [95% CI 23-38]) of 150 participants based on Abbott RealTime. Sensitivity of the Xpert HCV Viral Load assay for HCV RNA detection in plasma collected by venepuncture was 100·0% (95% CI 92·0-100·0) and specificity was 99·1% (95% CI 94·9-100·0). Sensitivity of the Xpert HCV Viral Load assay for HCV RNA detection in samples collected by finger-stick was 95·5% (95% CI 84·5-99·4) and specificity was 98·1% (95% CI 93·4-99·8). No adverse events caused by the index test or the reference standard were observed. IMPLICATIONS The Xpert HCV Viral Load test can detect active infection from a finger-stick sample, which represents an advance over antibody-based tests that only indicate past or previous exposure. FUNDING National Health and Medical Research Council (Australia), Cepheid, South Eastern Sydney Local Health District (Australia), and Merck Sharp & Dohme (Australia).
منابع مشابه
Human Immunodeficiency Virus (HIV)-Infected Patients Accept Finger Stick Blood Collection for Point-Of-Care CD4 Testing
INTRODUCTION HIV-infected patients require antiretroviral treatment for life. To improve access to care, CD4 enumeration and viral load tests have been redesigned to be used as point-of-care techniques using finger-stick blood. Accurate CD4 counting in capillary blood requires a free flowing blood drop that is achieved by blade incision. The aim of this study was to assess the attitude of the p...
متن کاملتعیین کمی بار ویروسی هپاتیت C با استفاده از روش Real-Time PCR In-House در بیماران آلوده به هپاتیت C در شهرستان خرم آباد
Background : Molecular diagnostic methods are among major tools in management of hepatitis C virus (HCV) in infected patients. Many studies have shown that viral load is associated with stage of infection and response to treatment. Therefore, the evaluation and quantification of viral load is very important. The goal of this study is implementation of inexpensive, yet accurate method for quanti...
متن کاملHepatitis C virus RNA quantitation in venous and capillary small-volume whole-blood samples.
Quantitation of hepatitis C virus (HCV) RNA in plasma and serum samples is a costly procedure in both time and reagents. Additionally, cell-associated viral RNA may not be detected. This study evaluated the accuracy of HCV RNA quantitation in small-volume whole-blood (WB) samples, which would be appropriate for point-of-care diagnostic devices. HCV RNA was extracted from 222 clinical plasma and...
متن کاملPoint -of -care testing (POCT) in molecular diagnostics: Performance evaluation of GeneXpert HCV RNA test in diagnosing and monitoring of HCV infection.
BACKGROUND Molecular testing at the point-of-care may turn out to be game changer for HCV diagnosis and treatment monitoring, through increased sensitivity, reduced turnaround time, and ease of performance. One such assay GeneXpert® has recently been released. OBJECTIVES Comparative analysis between performances of GeneXpert® and Abbott HCV-RNA was done. STUDY DESIGN 174 HCV infected patien...
متن کاملEvaluation of Preventive Interventions in Reporting Needle Stick Injuries among Health Care Workers
Background and Objective: Needle stick injuries (NSIs) are a common potential risk for healthcare workers. The aim of this study was to evaluate preventive interventions against needle stick injury incidents among HCWs. Methods: Seven hospitals in the Iranian Chaharmahal-VA-Bakhtiari Province were surveyed between March 2008 to March 2013. Data of the needle stick injuries of healthcare wor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The lancet. Gastroenterology & hepatology
دوره 2 7 شماره
صفحات -
تاریخ انتشار 2017