Scientific Review: Conical Seal Design
ثبت نشده
چکیده
A key feature of the ASTRA TECH Implant System BioManagement Complex is the design of the implant-abutment connection, i.e. the Conical Seal Design. This design feature has been part of the implant system since 1985, thus all clinical documentation available includes results on this key feature. This review includes technical literature focusing on evaluating the Conical Seal Design, using appropriate methodological set ups.
منابع مشابه
Rotordynamic Forces from Discharge- to-Suction Leakage Flows in Centrifugal Pumps
The rotordynamic forces generated by the fluid flow through the impeller leakage path of a centrifugal pump are now well established. The present paper examines the effects of modifying the leakage path geometry by changing the front shroud, from a conical shape to a more typical curved design, and the effects of low pressure seal design on these forces. It is found that only the cross-coupled ...
متن کاملOPTIMUM DESIGN OF FILAMENT–WOUND LAMINATED CONICAL SHELLS FOR BUCKLING USING THE PENALTY FUNCTION
Optimum laminate configuration for minimum weight of filament–wound laminated conical shells subject to buckling load constraint is investigated. In the case of a laminated conical shell the thickness and the ply orientation (the design variables) are functions of the shell coordinates, influencing both the buckling load and its weight. These effects complicate the optimization problem consider...
متن کاملA review of functionally graded thick cylindrical and conical shells
Thick shells have attracted much attention in recent years as intelligent and functional graded materials because of their unique properties. In this review paper, some critical issues and problems in the development of thick shells made from Functionally graded piezoelectric material (FGPM) are discussed. This review has been conducted on various types of methods which are available for thick ...
متن کاملA 30 T pulsed magnet with conical bore for synchrotron powder diffraction.
We report on the design, construction, and operation of a horizontal field, 30 T magnet system with a conical bore optimized for synchrotron x-ray powder diffraction. The magnet offers ±31° optical access downstream of the sample, which allows to measure a sufficiently large number of Debye rings for an accurate crystal structure analysis. Combined with a 290 kJ generator, magnetic field pulses...
متن کاملA versatile and reliably reusable ultrahigh vacuum viewport.
We present a viewport for use in ultrahigh vacuum (UHV) based upon the preflattened solder seal design presented in earlier work [Cox et al., Rev. Sci. Instrum. 74, 3185 (2003)]. The design features significant modifications to improve long term performance. The windows have been leak tested to less than 10(-10) atm cm(3)/s. From atom number measurements in an optical dipole trap loaded from a ...
متن کامل