Improved fast multi-station water-fat imaging at 3T

نویسندگان

  • Melissa Hooijmans
  • Oleh Dzyubachyk
  • Kay Nehrke
  • Peter Koken
  • Maarten Versluis
  • Hermien Kan
  • Peter Boernert
چکیده

Purpose: To show the effect and the increased scan efficiency offered by DREAM-based B1 + shimming in fast whole body fat/water imaging at 3T. Introduction: High field whole-body imaging is a promising technique for quantitative MRI. However, at 3T and above, wave propagation effects can have serious effects on RF field homogeneity (B1 ). This results in spatially varying image contrast and SNR which can compromise clinical diagnosis and makes quantification very difficult (1). Parallel transmission can mitigate this problem via B1 + shimming for which knowledge of transmit sensitivities is needed, making B1 + mapping indispensable. The RF distribution within the body can change substantially from station to station, for example between head and abdomen, and very fast B1 + mapping to facilitate appropriate RF shimming (2) is critical. Current two-channel B1 + mapping methodology requires a 15s breath-hold (2). The recently introduced Dual Refocusing Echo Imaging Mode (DREAM) approach (3) enabling single shot B1 + mapping within a fraction of a second, is therefore very promising, meeting the needs of many clinical applications. Methods: Whole-body fat-water images were acquired in 8 healthy subjects (24-45 years) using a 3T dual-transmit MRI system (Ingenia, Philips Healthcare, Best, the Netherlands). A multi-station, 3D, dual-echo mDixon FFE acquisition with 17 stacks of 24 contiguous axial slices was performed with the following scan parameters: (TR/TE1/TE2: 3.2/1.13/2.0ms, FA:5, voxel size: 1.91×1.91×5mm3). Each stack was preceded by a 2D B1 + DREAM calibration scan, centered in the middle of the stack (DREAM-parameters: voxel size: 5×5×10mm, STEAM α: 50°, imaging β: 5°, TEFID/TESTE/TR: 1.4/2.4/3.8 ms, shot duration: 150ms). Dual-channel DREAM B1 + mapping took roughly 1.3 seconds, with a waiting time of 1s between left and right channel acquisition. Additional DREAM maps were obtained in the conventional quadrature and in the B1 + shimmed mode for comparison. This was followed by the 3D mDixon scans B1 + shimmed according to the DREAM calibrations and in quadrature mode. Breath-holds were performed for the stacks in the pelvis and chest region with a maximum duration of 19s with the body coil being used for signal reception. For each stack we determined the coefficient of variation (CoV) and the mean for the two B1 + maps and entropy of the joint intensity histogram [5] of the 3D fat/water images. After grouping the stacks from all subjects in three zones classified as: legs, upper body and head, differences in CoV and joint entropy were assessed between the two B1 + regimes with a paired sample ttest and the Kolmogorov Smirnov test (p<0.05). Results: Whole-body fat/water images acquired in all subjects showed a consistent improvement in image quality using DREAM-based B1 + shimming (Fig.1). These improvements were visible in the higher image homogeneity and the consistency in image contrast (see the signal drop in the abdominal region in Fig.1a). The ratio of the joint histogram entropy confirms the improvements in image quality in the stacks covering the upper body region (legs p=0.58, upper body p<0.01)but not in the head (p=0.38). The improvement in image and contrast homogeneity was confirmed by an evaluation of the B1 + maps. A significant reduction in the CoV, which measures the inhomogeneity, was found especially in the abdominal / upper body region (quad=0.26±0.06, shim=0.15±0.04, p<0.01) with strong reduction in RF shading artifacts. In the stacks covering the legs (quad=0.18±0.04, shim=0.13±0.03, p<0.01), only minor improvements were present and the head region showed no improvements (quad=0.11±0.03, shim= 0.11±0.03, p=0.28). B1 + shimming also improved the mean B1 + level (Fig.1), which is important to maintain the image contrast homogeneity across the whole body. Discussion & Conclusion: In this study we showed that DREAM-based B1 + shimming per station in whole-body multi-station fat-water MR imaging gives significant improvements in image quality in comparison with the conventional quadrature mode at only minor costs of scanning time for the B1 + mapping. DREAM improves the workflow significantly, accelerating B1 + mapping by an order of magnitude compared to existing techniques. The improved RF performance, higher image quality and increased workflow will improve all whole-body imaging sequences. References: [1] Willinek et al. Radiology 2010;256:966-75. [2] Welch et al. ISMRM (2013) #1524. [3] Nehrke et al. MRM 2012;68:1517. [4] Eggers et al. MRM 2011;65:96-107. [5] Jäger et al. IEEE TMI 2009;28,1,137–150. Fig.1. Coronal (a,b,c,d) and axial (e,f,g,h) reformats of whole body f/w images using DREAMbased B1 + shimming (c,d,g,h,j) and the conventional quadrature excitation (a,b,e,f,i), together with the adjoining axial DREAM B1 + maps (i,j). Graphs: mean B1 + (top), CoV (middle) and image entropy ratio (bottom) for each stack (feet:left, head:right) for the two B1 + regimes. F/w images in the leg region have been corrected for some station signal swaps during post-processing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac Imaging with Chemical Shift Based Water-Fat Separation at 3T

Introduction Chemical shift based water-fat separation techniques have been demonstrated for 1.5T cardiac imaging of several pathologies, including fatty infiltration of chronic infarction; arrhythmogenic right ventricular cardiomyopathy (ARVC); fatty tumors; and conditions such as myocarditis and pericarditis [1-4]. Higher field strengths (3T) are now often used in cardiac MRI due to improved ...

متن کامل

Spatially variable fat-water separation using short 2DRF pulses for fast imaging

5*560μs pulse (a) left: fat+water, right: water-only (b) left: water-only, right: signal null; (c) left: signal null, right: fat-only (d) left: fat-only, right: fat+water. Fig.2. (a) full FOV fat-water separation at 3T with a 5*1136μs pulse; (b) rFOV separation (RFOV=2) with a 9*1136μs pulse; (c) full FOV separation with a 5*720μs pulse; (d) spatially variable separations with a 5*560μs pulse. ...

متن کامل

Influence of fat on liver T 1 measurements using modified Look–Locker inversion recovery (MOLLI) methods at 3T

PURPOSE To characterize the effect of fat on modified Look-Locker inversion recovery (MOLLI) T1 maps of the liver. The balanced steady-state free precession (bSSFP) sequence causes water and fat signals to have opposite phase when repetition time (TR) = 2.3 msec at 3T. In voxels that contain both fat and water, the MOLLI T1 measurement is influenced by the choice of TR. MATERIALS AND METHODS ...

متن کامل

3T Coronary MRA using 3D Multi-interleaved Multi-echo Acquisition and VARPRO Fat-water Separation

Introduction: Coronary MR Angiography is a valuable tool for non-invasive assessment of coronary arteries. Presently, contrastenhanced, fat-saturated, ECG-triggered and navigator-gated 3D spoiled gradient-echo sequence is employed for whole-heart Coronary MRA at 3T. However, large static field variations at 3T frequently result in non-uniform fat-suppression over the field-of-view (FOV), obscur...

متن کامل

Real-time cardiac MRI at 3 tesla.

Real-time cardiac and coronary MRI at 1.5T is relatively "signal starved" and the 3T platform is attractive for its immediate factor of two increase in magnetization. Cardiac imaging at 3T, however, is both subtly and significantly different from imaging at 1.5T because of increased susceptibility artifacts, differences in tissue relaxation, and RF homogeneity issues. New RF excitation and puls...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013