High-Resolution Postcontrast Time-of-Flight MR Angiography of Intracranial Perforators at 7.0 Tesla

نویسندگان

  • Anita A. Harteveld
  • Laurens J. L. De Cocker
  • Nikki Dieleman
  • Anja G. van der Kolk
  • Jaco J. M. Zwanenburg
  • Pierre A. Robe
  • Peter R. Luijten
  • Jeroen Hendrikse
چکیده

BACKGROUND AND PURPOSE Different studies already demonstrated the benefits of 7T for precontrast TOF-MRA in the visualization of intracranial small vessels. The aim of this study was to assess the performance of high-resolution 7T TOF-MRA after the administration of a gadolinium-based contrast agent in visualizing intracranial perforating arteries. MATERIALS AND METHODS Ten consecutive patients (7 male; mean age, 50.4 ± 9.9 years) who received TOF-MRA at 7T after contrast administration were retrospectively included in this study. Intracranial perforating arteries, branching from the parent arteries of the circle of Willis, were identified on all TOF-MRA images. Provided a TOF-MRA before contrast administration was present, a direct comparison between pre- and postcontrast TOF-MRA was made. RESULTS It was possible to visualize intracranial perforating arteries branching off from the entire circle of Willis, and their proximal branches. The posterior cerebral artery (P1 and proximal segment of P2) appeared to have the largest number of visible perforating branches (mean of 5.1 in each patient, with a range of 2-7). The basilar artery and middle cerebral artery (M1 and proximal segment M2) followed with a mean number of 5.0 and 3.5 visible perforating branches (range of 1-9 and 1-8, respectively). Venous contamination in the postcontrast scans sometimes made it difficult to discern the arterial or venous nature of a vessel. CONCLUSION High-resolution postcontrast TOF-MRA at 7T was able to visualize multiple intracranial perforators branching off from various parts of the circle of Willis and proximal intracranial arteries. Although confirmation in a larger study is needed, the administration of a contrast agent for high-resolution TOF-MRA at 7T seems to enable a better visualization of the distal segment of certain intracranial perforators.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of pre- and postcontrast 3D time-of-flight MR angiography for the evaluation of distal intracranial branch occlusions in acute ischemic stroke.

BACKGROUND AND PURPOSE Three-dimensional time-of-flight (TOF) MR angiography is used routinely in stroke workup to detect arterial occlusions, but a major drawback is its inadequate depiction of vessels with slow or in-plane flow. We hypothesized that the use of contrast-enhanced MR angiography improves delineation of vessels with diminished or absent flow on precontrast MR angiograms. METHOD...

متن کامل

Contrast-enhanced MR angiography at 3T in the evaluation of intracranial aneurysms: a comparison with time-of-flight MR angiography.

The combination of 3T and parallel-acquisition techniques holds promise for improved performance of contrast-enhanced MR angiography (MRA), in terms of speed, spatial resolution, and coverage. We present a comparison of 2 MRA techniques, including time-of-flight (TOF) and contrast-enhanced MRA, for detection and evaluation of intracranial aneurysms. Our results show that contrast-enhanced MRA w...

متن کامل

Time-of-flight magnetic resonance angiography of the canine brain at 3.0 Tesla and 7.0 Tesla.

OBJECTIVE To evaluate the ability of 2-D time-of-flight (ToF) magnetic resonance angiography (MRA) to depict intracranial vasculature and compare results obtained with 3.0- and 7.0-T scanners in dogs. ANIMALS 5 healthy Beagles. PROCEDURES 2-D ToF-MRA of the intracranial vasculature was obtained for each dog by use of a 3.0-T and a 7.0-T scanner. Quantitative assessment of the images was obt...

متن کامل

Three-dimensional time-of-flight MR angiography in the evaluation of intracranial aneurysms treated with Guglielmi detachable coils.

BACKGROUND AND PURPOSE Intravascular treatment of intracranial aneurysms is a relatively new therapeutic technique and long-term controlled angiographic trials are needed to assess persistence of aneurysm occlusion. Our purpose was to evaluate the effectiveness of 3D time-of-flight (3D-TOF) MR angiography as a noninvasive screening tool in the follow-up of cerebral aneurysms treated with Guglie...

متن کامل

Diagnosis of intracranial aneurysms: accuracy of MR angiography at 0.5 T.

PURPOSE Our goal was to determine the accuracy of MR angiography at 0.5 T for the diagnosis of intracranial aneurysms. METHODS We retrospectively studied 140 patients, 70 with acute subarachnoid hemorrhage, who were either at high or low risk for intracranial aneurysm. Three-dimensional time-of-flight MR angiography was typically performed to cover the circle of Willis, with a volume thicknes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015