Automated and Manual Direct Methods for the Determination of Blood Urea.

نویسندگان

  • W H MARSH
  • B FINGERHUT
  • H MILLER
چکیده

Automated and manual direct methods for the determination of urea in blood or serum are described. These methods determine urea by the colored product formed when urea, in relatively weak acid solution, reacts with diacetyl monoxime in the presence of thiosemicarbazide and ferric ion. Results are compared with those obtained by urease conversion of urea to ammonia and measurement of the ammonia by nesslerization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fragmentation measurement using image processing

In this research, first of all, the existing problems in fragmentation measurement are reviewed for the sake of its fast and reliable evaluation. Then, the available methods used for evaluation of blast results are mentioned. The produced errors especially in recognizing the rock fragments in computer-aided methods, and also, the importance of determination of their sizes in the image analysis ...

متن کامل

مقایسه شمارش خودکار با شمارش دستی نوتروفیل‌ها در تشخیص پریتونیت باکتریال خود به خودی

Introduction: Spontaneous bacterial peritonitis (SBP) is a prevalent complication in the patients with cirrhosis and ascites, which leads to high intrahospital mortality. Diagnosis is made when ascetic fluid neutrophils is ≥250 cells/mm3. Manual counting of neutrophils is time-consuming, technically difficult, expensive and in many cases individual-dependent. In contrast, automated counting ...

متن کامل

Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images

Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...

متن کامل

Validity of Selected WBC Differentiation Flags in Sysmex XT-1800i

Background: Automatic Cell Counter devises make the CBC differential very easy and delivering the results in few second. However, the problem with this device is facing a flag requires a time-consuming microscopic review of the specimen which causes unacceptable wait times for patient as well as costs for laboratories. In this study, we calculated the validity of WBC d...

متن کامل

Automated methods for blood glucose and urea with adaptation for simultaneous determination.

Automated blood glucose and urea nitrogen procedures have been modified for use with the Technicon 15-mm. tubular flow-cell colorimeter to take advantage of the resulting increased sensitivity and economy. Flow diagrams for these procedures as well as for the simultaneous determination of glucose and urea are presented. Recovery and reproducibility data are given to indicate the reliability of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 11  شماره 

صفحات  -

تاریخ انتشار 1965