Comparison of the action spectra and relative DNA absorbance spectra of microorganisms: information important for the determination of germicidal fluence (UV dose) in an ultraviolet disinfection of water.
نویسندگان
چکیده
The action spectra of Bacillus subtilis spores (ATCC6633) and Salmonella typhimurium LT2 were characterized using physical radiometry for irradiance measurements and a multiple target model to interpret the inactivation kinetics. The observed action spectrum of B. subtilis spores deviated significantly from the relative absorbance spectrum of the DNA purified from the spores, but matched quite well with the relative absorbance spectrum of decoated spores. The action spectrum of B. subtilis spores determined in this study was statistically different from those reported in previous studies. On the other hand, the action spectrum of S. typhimurium bacteria matched quite well with the relative absorbance spectrum of DNA extracted from vegetative cells, except in the region below 240nm. It is concluded that the common use of the relative DNA absorbance spectrum as a surrogate for the germicidal action spectrum can result in systematic errors when evaluating the performance of a polychromatic UV light reactors using bioassays. For example, if the weighted germicidal fluence (UV dose) calculated using the relative DNA absorbance spectrum as the germicidal weighting factor is found to be 40mJcm(-2) for a medium pressure lamp UV reactor, that calculated using the relative action spectrum of B. subtilis spores, as determined in this study, would be 66mJcm(-2).
منابع مشابه
Spectral sensitivity of Bacillus subtilis spores and MS2 coliphage for validation testing of ultraviolet reactors for water disinfection.
The microbicidal UV fluence under polychromatic radiation from UV lamps is typically measured using the DNA absorbance spectrum as a weighting factor for the relative wavelength effectiveness. However, this DNA-based weighting does not necessarily match the spectral sensitivity of the microorganism being tested. Bacillus subtilis spores are often used for UV reactor validation in Europe, while ...
متن کاملAction spectra for validation of pathogen disinfection in medium-pressure ultraviolet (UV) systems.
Ultraviolet (UV) reactors used for disinfecting water and wastewater must be validated and monitored over time. The validation process requires understanding the photochemical properties of the pathogens of concern and the challenge microorganisms used to represent them. Specifically for polychromatic UV systems, the organisms' dose responses to UV light and their sensitivity across the UV spec...
متن کاملImpact of Particle Aggregated Microbes on UV Disinfection. II: Proper Absorbance Measurement for UV Fluence
Ultraviolet UV absorbance measurements are subject to significant error using a standard spectrophotometer when particles or aggregates that scatter light are present. True UV absorbance for highly turbid waters should be measured using integrating sphere IS spectrophotometry that allows the collection of reflected and transmitted radiation simultaneously. This is especially important when the ...
متن کاملA comparative Monte Carlo study on 6MV photon beam characteristics of Varian 21EX and Elekta SL-25 linacs
Background: Monte Carlo method (MC) has played an important role in design and optimization of medical linacs head and beam modeling. The purpose of this study was to compare photon beam features of two commercial linacs, Varian 21EX and Elekta SL-25 using MCNP4C MC code. Materials and Methods: The 6MV photon beams of Varian 21EX and Elekta Sl-25 linacs were simulated based on manufacturers pro...
متن کاملCFD Simulation of UV Disinfection Reactor for Applesauce with a Low UV Absorption Coefficient
In this study, a Computational Fluid Dynamics (CFD) model was developed to evaluate ultraviolet disinfection applesauce reactor. To simulate UV reactors, three sets of equations, including hydrodynamics, radiation and species mass conservation were solved simultaneously. The Realizable k-e turbulence model and the discrete ordinate method were used to find the UV radiation profile through the r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Water research
دوره 43 20 شماره
صفحات -
تاریخ انتشار 2009