Impedance Changes Indicate Proximal Ventriculoperitoneal Shunt Obstruction In Vitro
نویسندگان
چکیده
Extracranial cerebrospinal fluid (CSF) shunt obstruction is one of the most important problems in hydrocephalus patient management. Despite ongoing research into better shunt design, robust and reliable detection of shunt malfunction remains elusive. The authors present a novel method of correlating degree of tissue ingrowth into ventricular CSF drainage catheters with internal electrical impedance. The impedance based sensor is able to continuously monitor shunt patency using intraluminal electrodes. Prototype obstruction sensors were fabricated for in-vitro analysis of cellular ingrowth into a shunt under static and dynamic flow conditions. Primary astrocyte cell lines and C6 glioma cells were allowed to proliferate up to 7 days within a shunt catheter and the impedance waveform was observed. During cell ingrowth a significant change in the peak-to-peak voltage signal as well as the root-mean-square voltage level was observed, allowing the impedance sensor to potentially anticipate shunt malfunction long before it affects fluid drainage. Finite element modeling was employed to demonstrate that the electrical signal used to monitor tissue ingrowth is contained inside the catheter lumen and does not endanger tissue surrounding the shunt. These results may herald the development of "next generation" shunt technology that allows prediction of malfunction before it affects patient outcome.
منابع مشابه
Evaluation of ventriculoperitoneal shunt malfunction regarding ventricular catheter placement
AbstractBackgroundline of treatment for management of hydrocephalus despite available new techniques andsystems of shunting. Associated complications should be recognized and managed properly,but the most recognized complications are shunt obstruction which its prevalencethrough surgical approach is discussed here. Two approaches (frontal and parietal) are usedto insert ventriculoperitoneal shu...
متن کاملLaparoscopic revision of the distally obstructed ventriculoperitoneal shunt.
AIM Evaluation of the laparoscopic assisted revision of the ventriculoperitoneal shunt as an alternative technique to the traditional laparotomy. MATERIAL AND METHODS Out of 1181 elective neurosurgical procedures have been done from January 2009 to December 2010. There are 98 (8.2%) ventriculoperitoneal shunt procedures. New shunt insertion was performed 41 times (41.9%) a...
متن کاملEvaluation of ventriculoperitoneal shunt malfunction regarding ventricular catheter placement
Background: Shunting procedures specifically ventriculoperitoneal shunts are the main line of treatment for management of hydrocephalus despite available new techniques and systems of shunting. Associated complications should be recognized and managed properly,but the most recognized complications are shunt obstruction which its prevalence through surgical approach is discussed here. Two approa...
متن کاملEffect of Electromagnetic Navigated Ventriculoperitoneal Shunt Placement on Failure Rates
OBJECTIVE To evaluate the effect of electromagnetic (EM) navigation system on ventriculoperitoneal (VP) shunt failure rate through comparing the result of standard shunt placement. METHODS All patients undergoing VP shunt from October 2007 to September 2010 were included in this retrospective study. The first group received shunt surgery using EM navigation. The second group had catheters ins...
متن کاملSuccess rates and complications of ventriculoperitoneal and ventriculoatrial shunting: A systematic review
Background and Aims: The insertion of ventriculoperitoneal (VP) and ventriculoatrial (VA) shunts is the first-line treatment of patients with hydrocephalus and normal-pressure hydrocephalus. The provision of a safety profile for shunting in the treatment of hydrocephalus patients is very important. This study aimed to determine the success rates and complications of VP and VA shunting in patien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE transactions on bio-medical engineering
دوره 62 12 شماره
صفحات -
تاریخ انتشار 2015