Biocompatibility of Orthopaedic Implants on Bone Forming Cells

نویسندگان

  • ANITA KAPANEN
  • Yrjö Konttinen
  • Jukka Lausmaa
چکیده

Reindeer antler was studied for its possible use as a bone implant material. A molecular biological study showed that antler contains a growth factor promoting bone formation. Ectopic bone formation assay showed that antler is not an equally effective inducer as allogenic material. Ectopic bone formation assay was optimised for biocompatibility studies of orthopaedic NiTi implants. Ti-6Al-4V and stainless steel were used as reference materials. The assay showed differences in bone mineral densities, with superior qualities in NiTi. The rate of endochondral ossification varied between the implants, NiTi ossicles had larger cartilage and bone areas than ossicles of the two other materials. The cytocompatibility of NiTi was studied with three different methods. Cell viability, cell adhesion and TGF-β1 concentration were assessed in ROS-17/2.8 cell cultures. Cells grown on NiTi had better viability than cells grown on pure nickel or stainless steel. Cell attachment on the materials was studied with paxillin staining of focal contacts. The number of focal contacts was clearly higher in cells grown on NiTi than in cells grown on pure titanium, pure nickel or stainless steel. TGF-β1 concentration was measured with ELISA. The results showed that there was only some minor variation between NiTi, pure titanium and stainless steel. Nickel showed a lower TGF-β1 concentration. Taken together, these results suggest that NiTi is well tolerated by ROS-17/2.8 cells. The cytocompatibility of stainless steel is not so good as that of NiTi. The same tests were used to study the effects of the surface roughness of the implant on cytocompatibility. Three different surface roughness grades were compared in cell cultures on NiTi and titanium alloy discs. Titanium alloy was subjected to two different heat treatments, to compare the effects of the treatments on cytocompatibility. The studies showed that NiTi had a lesser impact on cell viability and attachment than titanium alloy. Further, rough NiTi was found to be a better tolerated surface than the others. In this study, heat treatment of titanium alloy at +850° C did not interfere with cell viability or attachment, as did the +1050° C treatment of the alloy. On the contrary, TGF-β1 concentrations decreased on the +850° C treated alloy and were approximately same on the +1050° C treated alloy and on NiTi.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Similarities and differences in coatings for magnesium-based stents and orthopaedic implants

Magnesium (Mg)-based biodegradable materials are promising candidates for the new generation of implantable medical devices, particularly cardiovascular stents and orthopaedic implants. Mg-based cardiovascular stents represent the most innovative stent technology to date. However, these products still do not fully meet clinical requirements with regards to fast degradation rates, late restenosi...

متن کامل

Effects of Er: YAG, 980 nm and 810 nm Diode Lasers Irradiation on Biocompatibility of SLA Titanium Disks Using SaOs2 Cells Morphology

Objectives The use of lasers for the treatment of periimplant hard and soft tissues is now refmore than ever before. Achieving bone integrity. The aim of this study is to evaluate the effects of Er:YAG, 980 nm and 810 nm diode lasers irradiation on biocompatibility of SLA titanium disks by SaOs2 cells morphology. Methods In this in-vitro study sixty sterile titanium disks with SLA surface were...

متن کامل

Bioactive Coatings for Orthopaedic Implants—Recent Trends in Development of Implant Coatings

Joint replacement is a major orthopaedic procedure used to treat joint osteoarthritis. Aseptic loosening and infection are the two most significant causes of prosthetic implant failure. The ideal implant should be able to promote osteointegration, deter bacterial adhesion and minimize prosthetic infection. Recent developments in material science and cell biology have seen the development of new...

متن کامل

How Nanotechnology can Really Improve the Future of Orthopedic Implants and Scaffolds for Bone and Cartilage Defects

The osteointegration of the orthopaedic implants could improve the biocompatibility and the life span of the implants. The ideal implants should be made by materials easily colonized by bone-forming cells (osteoblasts), which can synthesize new bone matrix. Some implant materials are not often compatible with osteoblasts, but rather they promote the formation of soft connective tissue. There ar...

متن کامل

Molecular engineering of an orthopaedic implant: from bench to bedside.

The use of metallic implants has revolutionised the practice of orthopaedic surgery. While the safety and biocompatibility of these devices are excellent, a small percentage becomes infected. These infections are due to the formation of a biofilm that harbours bacteria encased in a complex extracellular matrix. The matrix serves as a barrier to immune surveillance as well as limiting the biocid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002