Micro-transesophageal Echocardiography Guided Mitral Valve Repair After Balloon Dilation for Aortic Valve Stenosis in a Small Infant

نویسندگان

  • Xiao-Jing Ma
  • Guo-Ying Huang
  • Jing Zhang
چکیده

1277 To the Editor: Transoesophageal echocardiography (TEE) plays an important role in monitoring, guiding, and evaluating the surgical repair of congenital heart disease (CHD).[1,2] However, the large size of the currently available TEE probes limits their application in pediatric cases, especially in small infants. Recently, a miniaturized micro‐TEE probe compatible in neonates has been introduced for clinical use. However, limited experiences with micro‐TEE have been reported. Here, we reported a special small infant case, whose mitral valve was damaged after balloon dilation for aortic valve stenosis (AS), the infant went on to receive surgical repair under micro‐TEE guidance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel approach: trans-ascending aorta balloon aortic valvuloplasty via sternotomy for treating severe valvular aortic stenosis in a low-weight infant.

BACKGROUND Severe congenital aortic stenosis in infants is a life-threatening congenital heart anomaly that is typically treated using percutaneous balloon aortic valvuloplasty. METHODS The usual route is the femoral artery under radiographic guidance. However, this procedure may be limited by the small size of the femoral artery in low-weight infants. An infant weighing only 7 kg with severe...

متن کامل

سودوآنوریسم فیستولیزه شده فیبروز بین دریچه ای میترال و آئورت در یک بیمار پس از عمل جراحی بای پس عروق کرونر

Pseudoaneurysm is a rare condition in the region of the fibrous body between the mitral and aortic valve, the mitral-aortic intervalvular fibrosa (MAIVF), that has been reported as a sequela of endocarditis and surgical trauma. MAIVF rarely occurs on native aortic valve after infective endocarditis (IE). It is often fatal because of its rapid progress, high rates of rupture and recurrence, and ...

متن کامل

Rapid pannus formation: a rare cause of mitral stenosis following successful mitral valve repair.

helpful? Benefits, costs and how to learn. Eur Heart J 2014;35:69–76. 34. Bartel T, Müller S. Device closure of interatrial communications: peri-interventional echocardiographic assessment. Eur Heart J Cardiovasc Imaging 2013;14:618–24. 35. Melby SP, Moon MR, Lindman BR, Bailey MS, Hill LL, Damiano RJ. Impact of pulmonary hypertension on outcomes after aortic valve replacement for aortic valve ...

متن کامل

Transvenous mitral valve replacement after failure of surgical ring annuloplasty.

To the Editor: Mitral valve repair is the preferred treatment for itral regurgitation (MR). However, failure or recurrence of MR ight occur. Re-operation might carry a high risk in patients with omorbidities. A few reports have suggested the feasibility of ranscatheter mitral valve replacement after failure of surgical ring nnuloplasty (1–4). We report here the first series of transvenous itral...

متن کامل

Apical aortic valve implantation in a patient with a mechanical valve prosthesis in mitral position.

A 67-year-old man diagnosed with severe aortic stenosis was admitted to our institution with pulmonary edema. The patient had a history of severe pulmonary fibrosis (total lung capacity, 57% of predicted value; diffusing capacity for carbon monoxide, 33% of predicted value) and had undergone coronary bypass grafting and mitral valve replacement with a St Jude mechanical valve (St Jude Medical, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 128  شماره 

صفحات  -

تاریخ انتشار 2015