Tomography by the maximum entropy method for the W7-AS and W7-X multichannel bolometer systems
نویسنده
چکیده
Amaximum entropy approach has been applied to the tomographic inversion of the line integrated measurements of radiation power ux by a multichannel bolometer system. This method was applied to a H-mode discharge in the W7-AS stellarator, with increasing radiation from the plasma core after the transition being observed. Also a neutral beam injection discharge was investigated, and the time evolution of a marfe was documented. This method has also been applied to the preliminary design of a multi-camera system for full tomographic reconstruction in the W7-X stellarator. In addition, measurements with wire mesh shielded metal foil bolometers have been carried out and the shielding of these bolometers from microwaves produced by the 140 GHz gyrotrons used for electron cyclotron heating (ECRH) has been demonstrated.
منابع مشابه
Design criteria of the bolometer diagnostic for steady-state operation of the W7-X stellarator.
A bolometric diagnostic system with features necessary for steady-state operation in the superconducting stellarator W7-X was designed. During a pulse length of 1800 s with an ECRH (electron cyclotron resonance heating) power of 10 MW, the components suffer not only from a large thermal load but also from stray radiation of the nonabsorbed isotropic microwaves. This paper gives an overview of t...
متن کاملComparative Divertor-Transport Study for Helical Devices
Using the island divertors (ID) of W7-AS and W7-X and the helical divertor (HD) of LHD as examples, the paper presents a comparative divertor transport study for three typical helical devices of different machine-size following two distinct divertor concepts, aiming at identifying common physics issues/effects for mutual validation and combined studies. Based on EMC3/EIRENE simulations supporte...
متن کاملSynthetic Spectral Fits to the Type Ia Supernova 1994 D in NGC 4526
We have fit the normal, well observed, Type Ia Supernova (SN Ia) SN 1994D with non-LTE spectra of the deflagration model W7. We find that well before maximum luminosity W7 fits the optical spectra of SN 1994D. After maximum brightness the quality of the fits weakens as the spectrum forms in a core rich in iron peak elements. We show the basic structure of W7 is likely to be representative of th...
متن کاملDesign criteria of the bolometer diagnostic for steady- state operation of the W7-X stellaratora
• A submitted manuscript is the author's version of the article upon submission and before peer-review. There can be important differences between the submitted version and the official published version of record. People interested in the research are advised to contact the author for the final version of the publication, or visit the DOI to the publisher's website. • The final author version ...
متن کاملStructure of the Inhibitor W7 Bound to the Regulatory Domain of Cardiac Troponin C†
The calmodulin antagonist W7 binds to troponin C in the presence of Ca(2+) and inhibits striated muscle contraction. This study integrates multiple data into the structure of the regulatory domain of human cardiac troponin C (cNTnC) bound to Ca(2+) and W7. The protein-W7 interface is defined through a three-dimensional {(1)H,(13)C}-edited-{(1)H,(12)C}-detected NOESY NMR experiment, and other as...
متن کامل