Assessment of placental vascularization by three-dimensional power Doppler "vascular biopsy" in normal pregnancies.
نویسندگان
چکیده
AIM To describe the evolution of placental vascularization during a normal course of gestation and the blood flow 3D power Doppler indices obtained by "placental vascular biopsy." METHODS A prospective study was carried out on 99 normal singleton pregnancies from 14 to 40 weeks. Placental vascularization was evaluated by 3D power Doppler ("placental biopsy"). The spherical volume acquired was analyzed using the VOCAL imaging program (Virtual Organ Computer-aided AnaLysis). Three vascular indices, vascularization index (VI), flow index (FI), and vascularization-flow index (VFI), were calculated. Equations and regression coefficients for placental volume and vascular indices (VI, FI, VFI) of the placental biopsy were calculated according to gestational age. Relationships between 3D placental flow indices and fetal growth parameters: biparietal diameter, head circumference, abdominal circumference, femur length, estimated fetal body weight, maximum systolic velocity (US), and resistance index in the umbilical artery (URI) were evaluated by calculating their correlation coefficients. RESULTS All 3D Doppler indices had a significant relationship with gestational age. The most significant relationship was observed for FI, and the least significant for VI (r=0.58, r=0.29, respectively; P<0.01 for both). The FI increased linearly with gestation, whereas the VI showed a dispersion of values with a plateau from the 30th week onwards and a decrease from 37th week to the end of pregnancy. The VFI behaved as a combination of both VI and FI indices from which it was derived. All 3D Doppler indices were significantly related to fetal biometric parameters, except VI and fetal weight. A significant correlation was observed between 3D Doppler indices and maximum systolic velocity and URI. CONCLUSIONS 3D power Doppler technique of placental vascular "biopsy" is an appropriate tool for routine evaluation of the human placental vascular tree during gestation. 3D Doppler indices change as pregnancy progresses and are significantly related with fetal biometry and umbilical artery Doppler velocimetry.
منابع مشابه
Reproducibility of placental volume and vasculature indices obtained by 3-dimensional power Doppler sonography.
OBJECTIVE The purpose of this study was to evaluate the reproducibility of 3-dimensional (3D) power Doppler assessment of placental volumes and vascularization before adopting these in routine evaluation of normal and complicated pregnancies. METHODS A prospective study was performed on 30 normal singleton pregnancies from 11 to 14 weeks. To evaluate placental vascularization, 3D power Dopple...
متن کاملAnalysis of placental vascularization by means of 3D Power Doppler in women pregnant following oocyte donation.
OBJECTIVE To analyze the differences in placental perfusion in pregnancies following oocyte donation compared to spontaneous pregnancies. PARTICIPANTS AND METHODS A total of 33 patients who became pregnant after oocyte donation are studied and compared to 42 spontaneously pregnant participants. A 3-dimensional Power Doppler is used to obtain 3 placental volumes. Of each volume, 3 portions are...
متن کاملReduced placental volume and flow in severe growth restricted fetuses
OBJECTIVES To evaluate placental volume and vascular indices in pregnancies with severe fetal growth restriction and determine their correlations to normal reference ranges and Doppler velocimetry results of uterine and umbilical arteries. METHODS Twenty-seven fetuses with estimated weights below the 3rd percentile for gestational age were evaluated. Placental volume and vascular indices, inc...
متن کاملA Longitudinal Study of Three-dimensional Ultrasonographic Assessment of the Placenta in Uncomplicated Pregnancies
Copyright © 2012. Korean Society of Obstetrics and Gynecology Placental vascularization is important for normal pregnancy. The circulatory function of the placenta appears at an early stage of embryo-placental development and is strongly related to fetal growth, placental volume, and uterine blood flow. Therefore, adequate placental angiogenesis is critical for the establishment of normal place...
متن کاملThree-dimensional Power Doppler Ultrasound Study of the Placenta
Advanced ultrasound technology has been a valuable tool in the assessment of placental anatomy and physiology. Con ventional twodimensional (2D) sonography reveals placental morphological characteristics, 2D color Doppler can assess blood flow in the placenta, 2D power Doppler can evaluate placental vascular trees, and threedimensional (3D) ultra sound gives more detailed information on the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Croatian medical journal
دوره 46 5 شماره
صفحات -
تاریخ انتشار 2005