Feasibility Study of Online High-Spatial-Resolution MOSFET Dosimetry in Static and Pulsed X-Ray Radiation Fields
نویسندگان
چکیده
Improvements have been made in the measurement of dose profiles in several types of X-ray beams. These include 120-kVp X-ray beams from an orthovoltage X-ray machine, 6-MV Bremsstrahlung from a medical LINAC in conformal mode and the 50–200 keV energy spectrum of microbeams produced at the medical beamline station of the European Synchrotron Radiation Facility. Using a quadruple metal–oxide–semiconductor field-effect transistor (MOSFET) sensor chip in “edge on” mode together with a newly developed sensor readout system, the feasibility of online scanning of the profiles of quasi-static and pulsed radiation beams was demonstrated. Measurements of synchrotron pulsed microbeams showed that a micrometer-scale spatial resolution was achievable. The use of several MOSFETs on the same chip gave rise to the correction of misalignments of the oxide films of the sensor with respect to the microbeam, ensuring that the excellent spatial resolution of the MOSFET used in “edge-on” mode was fully utilized.
منابع مشابه
The effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...
متن کاملImproved spatial resolution by MOSFET dosimetry of an x-ray microbeam.
Measurement of the lateral profile of the dose distribution across a narrow x-ray microbeam requires a dosimeter with a micron resolution. We investigated the use of a MOSFET dosimeter in an "edge-on" orientation with the gate insulating oxide layer parallel to the direction of the beam. We compared results using this technique to Gafchromic film measurements of a 200 micrometer wide planar x-r...
متن کاملDesign of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies
Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...
متن کاملRectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector
Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...
متن کاملEvaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013
Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...