Rapid identification and susceptibility testing using the VITEK 2 system using culture fluids from positive BacT/ALERT blood cultures.
نویسندگان
چکیده
BACKGROUND AND PURPOSE In order to reduce the turnaround time for laboratory diagnosis of bacteremia, the efficacy of identification and antimicrobial susceptibility testing using samples taken directly from positive BacT/ALERT standard aerobic and standard anaerobic blood culture bottles was evaluated. METHODS 160 positive blood culture bottles were examined and incubated at 35 degrees C in 5% carbon dioxide for 4-24 h, and an aliquot of the culture fluid was Gram stained. Samples containing Gram-negative bacilli were inoculated on VITEK 2 ID-GNB (identification-Gram-negative bacilli) and AST (antimicrobial susceptibility testing)-GN04 cards, and those containing Gram-positive cocci were inoculated on ID-GPC (identification-Gram-positive cocci) and AST-P526 cards. The same samples were also examined by the standard method, involving subculture from positive BacT/ALERT standard blood culture bottles. RESULTS Eighty seven of 97 Gram-negative bacilli (89.7%) and 21 of 63 Gram-positive cocci (33.3%) were correctly identified to the species level. For antimicrobial susceptibility testing, the direct method had an overall error rate of 5.4% for Gram-negative bacilli, with 0.9% very major, 0.9% major, and 3.6% minor discrepancies compared to the standard method. The overall error rate in antimicrobial susceptibility testing for the 13 Staphylococcus spp. was 10.3%, with 6.0% very major, 2.6% major, and 1.7% minor discrepancies. CONCLUSION These data suggest that VITEK 2 cards inoculated with samples taken directly from positive Bact/ALERT blood culture bottles would provide acceptable identification and antimicrobial susceptibility testing results for Gram-negative bacilli, but not for Gram-positive cocci. Compared to the standard method, the direct method would reduce turnaround time by at least 24 h.
منابع مشابه
Isolation, identification and antimicrobial susceptibility of brucella blood culture isolates.
UNLABELLED Isolation of slowly growing and fastidious Brucella spp strains from clinical specimens is difficult, because of varying factors, including species specificities, stadium of disease, and previous antibiotic treatment of the patients. The use of automated blood culture systems has overcome some cultivation problems. The automated identification system such as VITEK 2 compact allows mo...
متن کاملEvaluation of the VITEK 2 system for rapid direct identification and susceptibility testing of gram-negative bacilli from positive blood cultures.
This study explores the possibility of combining the BacT/Alert Microbial Detection System with the VITEK 2 system to achieve rapid bacterial identification and susceptibility testing. Direct inoculation of bacterial suspension to the VITEK 2 ID-GNB card and AST-NO09 card was made by differential centrifugation of blood cultures of organisms with gram-negative enteric bacillus-like morphology. ...
متن کاملThe Role of Vitek-2 Automated System in Identification and Susceptibility Testing of Gram Negative Rods in an Intensive Care Unit Patients in Egypt
The performance of automated Vitek-2 system was evaluated for the identification and antimicrobial susceptibility testing (AST) of most common Gram-negative bacilli in intensive care unit patients directly from BacT/ALERT positive blood cultures bottles. Direct inoculation of the positive blood cultures with the Vitek cards ID-GNB and AST-GN71 was compared with the standard inoculation method b...
متن کاملAccuracy of the VITEK® 2 system for a rapid and direct identification and susceptibility testing of Gramnegative rods and Gram-positive cocci in blood samples.
The performance of the VITEK® 2 system for direct rapid identification and antimicrobial susceptibility testing of the bacteria responsible for blood infections was determined. The isolates studied included 166 Gram-negative rods and 74 Gram-positive cocci from inpatients. Specially treated monomicrobial samples from positive blood culture bottles were directly inoculated into the VITEK 2 syste...
متن کاملDirect identification and susceptibility testing of positive blood cultures using high speed cold centrifugation and Vitek II system.
Compared to routine isolated colony-based methods, direct testing of bacterial pellets from positive blood cultures reduces turnaround time for reporting of antibiotic susceptibility. The aim of this study was to compare the accuracy, and precision, of a rapid method for direct identification and susceptibility testing of blood cultures with the routine method used in our laboratory, using Vite...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of microbiology, immunology, and infection = Wei mian yu gan ran za zhi
دوره 41 3 شماره
صفحات -
تاریخ انتشار 2008