Comparative study of lens solutions' ability to remove tear constituents.

نویسندگان

  • Steven Cheung
  • Holly Lorentz
  • Elizabeth Drolle
  • Zoya Leonenko
  • Lyndon W Jones
چکیده

PURPOSE The purpose of this study was to use atomic force microscopy to compare and characterize the cleaning abilities of a hydrogen peroxide-based system (HPS) and a polyhexamethylene biguanide-containing multipurpose solution (MPS) at removing in vitro deposited tear film constituents, as well as to determine deposition patterns on various silicone hydrogel contact lenses. METHODS Silicone hydrogel materials-balafilcon A (BA), lotrafilcon B (LB), and senofilcon A (SA)-were incubated for 1 week in an artificial tear solution (ATS) containing representative lipids, proteins, and salts from the tear film. Atomic force microscopy was used to resolve each lens before and after being cleaned overnight in HPS or MPS. Atomic force microscopy was used again to resolve HPS/MPS-cleaned lenses, which were reincubated in fresh ATS for 1 week, before and after an overnight clean in their respective cleaning solution. RESULTS Atomic force microscopy imaging was able to characterize lens deposits with high resolution. Lenses incubated in ATS revealed distinct differences in their deposition pattern across lens materials. The surface of BA contained about 20-nm-high deposits, whereas deposit heights up to 150 nm completely occluded the surface of SA. Lotrafilcon B lenses revealed clusters of deposits up to 90 nm. The use of either lens solution left trace amounts of tear film constituents, although components from the MPS were seen adsorbed onto the surface after cleaning. Surface roughness (Ra) measurements revealed a significant difference between ATS-incubated and HPS/MPS-cleaned SA and LB lenses (p < 0.05). Ra between first incubated and HPS/MPS-cleaned reincubated SA and LB was also significant (p < 0.05). CONCLUSIONS Unique variations in ATS deposition patterns were seen between lenses with atomic force microscopy. The application of both HPS and MPS removed most visible surface deposits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contact lens physical properties and lipid deposition in a novel characterized artificial tear solution

PURPOSE To characterize various properties of a physiologically-relevant artificial tear solution (ATS) containing a range of tear film components within a complex salt solution, and to measure contact lens parameters and lipid deposition of a variety of contact lens materials after incubation in this ATS. METHODS A complex ATS was developed that contains a range of salts, proteins, lipids, m...

متن کامل

Tear film, contact lens, and patient factors associated with corneal staining.

PURPOSE The purpose of this study was to examine ocular surface and tear film, contact lens, care solution, medical, and patient-related factors that are associated with corneal staining in contact lens wearers. METHODS In this cross-sectional/nested case-control study, in addition to the assessment of corneal staining with fluorescein, a variety of tear film and ocular surface, contact lens,...

متن کامل

In-vitro analysis of the microbicidal activity of 6 contact lens care solutions

BACKGROUND Contact lens-related infections are often associated with inadequate contact lens hygiene, and therefore, contact lens care products should be able to sufficiently minimise the amount of pathogens that are responsible for these infections. In 2001, the EN ISO 14729 was introduced to ensure adequate disinfection efficacy of contact lens care solutions, but this norm has recently been ...

متن کامل

Tear Film Evaluation in Contact Lens Wearers and Non Wearers

Background: Dry eye symptoms are more frequent in contact lens wearers than in non wearers. Dry eye is considered relatively common in contact lens wearers than non-wearers. However, there was no any report in our clinical setting that compared and addressed the issue related to dry eye and its symptom in contact lens wearers. The present study was conducted to compare pre-ocular tear film in c...

متن کامل

Corneal Cell Adhesion to Contact Lens Hydrogel Materials Enhanced via Tear Film Protein Deposition

Tear film protein deposition on contact lens hydrogels has been well characterized from the perspective of bacterial adhesion and viability. However, the effect of protein deposition on lens interactions with the corneal epithelium remains largely unexplored. The current study employs a live cell rheometer to quantify human corneal epithelial cell adhesion to soft contact lenses fouled with the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 91 9  شماره 

صفحات  -

تاریخ انتشار 2014