Value of Holter monitoring in predicting long-term efficacy and inefficacy of amiodarone used alone and in combination with class 1A antiarrhythmic agents in patients with ventricular tachycardia.

نویسندگان

  • S G Kim
  • S D Felder
  • I Figura
  • D R Johnston
  • L E Waspe
  • J D Fisher
چکیده

The value of two reported and two new ambulatory electrocardiographic (Holter) criteria was studied in 80 patients taking amiodarone for refractory recurrent sustained ventricular tachycardia. In the 80 patients, the four Holter criteria were as follows: I-85% or greater reduction of ventricular premature complexes and abolition of couplets and nonsustained ventricular tachycardia in 74 patients who had 10 or more ventricular premature complexes/h, or any couplets or nonsustained ventricular tachycardia/24 hours at baseline; II-abolition of nonsustained ventricular tachycardia in 51 patients who had nonsustained ventricular tachycardia at baseline; III-85% or greater reduction of ventricular premature complexes and abolition of nonsustained ventricular tachycardia in 64 patients who had 30 or more ventricular premature complexes/h at baseline; and IV-85% or greater reduction of ventricular premature complexes and abolition of nonsustained ventricular tachycardia in 73 patients who had 10 or more ventricular premature complexes/h at baseline. Amiodarone was judged effective in, respectively, 51 of 74, 44 of 51, 51 of 64 and 61 of 73 patients by criterion I, II, III or IV. During the follow-up period (19 +/- 20 months), there were 19 instances of recurrence of ventricular arrhythmia or sudden death. Actuarial arrhythmia-free survival rate at 24 months was 84, 74, 86 and 85%, respectively, in patients with efficacy by criterion I, II, III or IV and 61, 43, 48 and 39%, respectively, in patients with inefficacy (p less than 0.015 for all). Many patients with efficacy by Holter criteria, however, had a recurrence of arrhythmia, suggesting insensitivity of these Holter criteria.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective comparison of class IA, B, and C antiarrhythmic agents in combination with amiodarone in patients with inducible, sustained ventricular tachycardia.

BACKGROUND Clinical experience suggests that combinations of antiarrhythmic agents provide more effective control of ventricular tachyarrhythmias than does therapy with single agents. METHODS AND RESULTS Antiarrhythmic and electrophysiological effects of three class I antiarrhythmic agents, one from each subclass A, B, and C, were assessed in single use and in combination with amiodarone in p...

متن کامل

The antiarrhythmic efficacy of amiodarone and desethylamiodarone, alone and in combination, in dogs with acute myocardial infarction.

Antiarrhythmic activity of amiodarone's desethyl metabolite, which accumulates during oral amiodarone therapy, has been postulated to explain the delayed onset of antiarrhythmic effects during long-term amiodarone therapy. To determine their relative antiarrhythmic efficacy, amiodarone and its desethyl metabolite, desethylamiodarone, were administered to mongrel dogs with ventricular tachycardi...

متن کامل

Efficacy of antiarrhythmic drugs in patients with arrhythmogenic right ventricular disease. Results in patients with inducible and noninducible ventricular tachycardia.

BACKGROUND Ventricular tachyarrhythmias are the major clinical manifestation of arrhythmogenic right ventricular disease. Although antiarrhythmic therapy has been widely advocated, there is only limited information available on the efficacy of antiarrhythmic drugs in these patients. METHODS AND RESULTS The short- and long-term efficacies of various antiarrhythmic agents were retrospectively a...

متن کامل

Ablation for ventricular tachycardia during stable sinus rhythm.

Implantable cardioverter defibrillators (ICDs) can effectively terminate ventricular tachycardia (VT) when it occurs, but they do not prevent initiation of VT. There are several reasons why prevention of episodes is desirable. When VT is promptly and painlessly terminated by antitachycardia pacing, it can be asymptomatic. However, patients describe defibrillator shocks as terrible events that e...

متن کامل

Clinical efficacy and safety of intravenous Amiodarone in infants and children.

The effectiveness and safety of intravenous amiodarone in children are not well established. This study reviewed its use in 30 infants and children for life-threatening tachyarrhythmias: 18 patients (19 episodes) with supraventricular tachycardia, and 12 with ventricular tachycardia. Eighteen patients had structural heart defects with arrhythmias that occurred after surgery. The mean loading do...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 1987