CT scout z-resolution improvement with image restoration methods
نویسندگان
چکیده
Currently, new applications demand utilizing CT scout images for diagnostic purposes. However, many CT scout images cannot be used diagnostically due to their poor resolution, particularly in the direction of table movement. Spatial resolution generally can be improved with image restoration techniques. Based on the principles of Wiener filtering and inverse filtering, this paper presents a modified Wiener filtering approach in the frequency domain. The concept of equivalent target point spread function is introduced, which makes the restoration process steerable. Consequently, balancing resolution improvement with noise suppression is facilitated. Experiments compare the image quality with traditional inverse filtering and Wiener filtering. The modified Wiener filtering method has been shown to restore the scout image with higher resolution and lower noise.
منابع مشابه
Methods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space
Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...
متن کاملAssessment the effect of CT localizer parameter on radiation dose and image quality of GE CT spiral images, A phantom study
Introduction: Using computed tomography (CT) is increasing significantly in Iran and worldwide. Reduction of CT's radiation dose is a critical concern. The aim of this study was evaluating the effect of localizer kVp on spiral CT images when the tube current modulation (TCM) is activated. Materials and Methods: A special wedding cake phantom with circular in...
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کاملA CONSORT-compliant prospective randomized controlled trial: radiation dose reducing in computed tomography using an additional lateral scout view combined with automatic tube current modulation
BACKGROUND Radiation exposure has been a hot point in research field of computed tomography (CT). Recently, automated tube current modulation (ATCM) has emerged as an important technique to reduce radiation exposure. Many studies have shown that the difference in scout view would affect modulation. This prospective randomized controlled study is aimed to investigate the impact of an additional ...
متن کاملImage Restoration for Resolution Improvement of Digital Aerial Images: a Comparison of Large Format Digital Cameras
Within the paper a comparative quantification of the spatial image resolution for large-format digital airborne cameras will be presented. For this purpose, imagery of the Leica ADS40, the Intergraph Z/I-imaging DMC and the Vexcel UltraCamD were examined. The respective spatial resolutions are represented by means of the point spread function, which can be measured easily and reliably at image ...
متن کامل