MRI thermometry based on encapsulated hyperpolarized xenon.
نویسندگان
چکیده
A new approach to MRI thermometry using encapsulated hyperpolarized xenon is demonstrated. The method is based on the temperature dependent chemical shift of hyperpolarized xenon in a cryptophane-A cage. This shift is linear with a slope of 0.29 ppm °C(-1) which is perceptibly higher than the shift of the proton resonance frequency of water (ca. 0.01 ppm °C(-1)) that is currently used for MRI thermometry. Using spectroscopic imaging techniques, we collected temperature maps of a phantom sample that could discriminate by direct NMR detection between temperature differences of 0.1 °C at a sensor concentration of 150 μM. Alternatively, the xenon-in-cage chemical shift was determined by indirect detection using saturation transfer techniques (Hyper-CEST) that allow detection of nanomolar agent concentrations. Thermometry based on hyperpolarized xenon sensors improves the accuracy of currently available MRI thermometry methods, potentially giving rise to biomedical applications of biosensors functionalized for binding to specific target molecules.
منابع مشابه
Detection of brown adipose tissue and thermogenic activity in mice by hyperpolarized xenon MRI.
The study of brown adipose tissue (BAT) in human weight regulation has been constrained by the lack of a noninvasive tool for measuring this tissue and its function in vivo. Existing imaging modalities are nonspecific and intrinsically insensitive to the less active, lipid-rich BAT of obese subjects, the target population for BAT studies. We demonstrate noninvasive imaging of BAT in mice by hyp...
متن کاملHyperpolarized Xenon Brain MRI
Since hyperpolarized 129Xe MRI was first demonstrated in the lung, air space imaging using hyperpolarized noble gases (129Xe and 3He) has progressed at a rapid rate (Goodson, 2002; Zhou, 2011c). Owing to high lipid solubility, absence of background signal in biological tissue, non-invasiveness, lack of radioactivity, different relaxation to oxygenated and deoxygenated blood, and larger chemical...
متن کاملDistribution of Hyperpolarized Xenon in the Brain Following Sensory Stimulation: Preliminary MRI Findings
In hyperpolarized xenon magnetic resonance imaging (HP (129)Xe MRI), the inhaled spin-1/2 isotope of xenon gas is used to generate the MR signal. Because hyperpolarized xenon is an MR signal source with properties very different from those generated from water-protons, HP (129)Xe MRI may yield structural and functional information not detectable by conventional proton-based MRI methods. Here we...
متن کاملGenetically encoded reporters for hyperpolarized xenon magnetic resonance imaging.
Magnetic resonance imaging (MRI) enables high-resolution non-invasive observation of the anatomy and function of intact organisms. However, previous MRI reporters of key biological processes tied to gene expression have been limited by the inherently low molecular sensitivity of conventional (1)H MRI. This limitation could be overcome through the use of hyperpolarized nuclei, such as in the nob...
متن کاملHyperpolarized Noble Gas Magnetic Resonance Imaging
Introduction Hyperpolarized noble gas magnetic resonance imaging (HP gas MRI) is a new and innovative imaging method that has made it possible, for the first time, to obtain high resolution MR images of air-filled organs such as the lungs, as well as lipid rich tissue such as the brain. Unlike conventional MRI which relies on the detection of water protons in biological tissue, HP gas MRI is ba...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chemphyschem : a European journal of chemical physics and physical chemistry
دوره 11 16 شماره
صفحات -
تاریخ انتشار 2010