Differential Incidence and Morphology of Spasm According to Coronary Arterial Location by Intracoronary Ergonovine Spasm Provocation Testing.

نویسندگان

  • Shozo Sueda
  • Hiroaki Kohno
چکیده

BACKGROUND We reported less provoked spasm in the left circumflex artery (LCX) by acetylcholine testing compared with the left anterior descending artery (LAD) and right coronary artery (RCA), so we investigated the clinical characteristics of provoked spasm in the LCX by ergonovine (ER) testing.Methods and Results:We retrospectively analyzed 1,185 consecutive cases of intracoronary ER testing during 25 years. Maximal ER dose was 64 μg into the left coronary artery (LCA) and 40 μg into the RCA. Positive spasm was defined as a transient ≥90% narrowing and usual chest symptoms or ischemic ECG changes. Positive provoked spasm was recognized in 347 patients (29.3%), including 207 RCA spasms, 166 LAD spasms, and 79 LCX spasms. Spasm was provoked in the LCX significantly less than in the other vessels (P<0.001). LCX-provoked spasm was obtained in 79 patients consisting of 16 patients (20.3%) with triple-vessel spasm, 38 patients (48.1%) with double-vessel spasm and 25 patients (31.6%) with single-vessel spasm. Less than 70% patients with LCX-provoked spasm had multiple spasms, whereas approximately 60% patients had single-vessel spasm in the RCA (64.3%) or LAD (59.6%). In 25 patients with LCX single-vessel spasm, 18 patients (72.0%) had a focal spasm. CONCLUSIONS Under maximal ER dose of 64 μg into the LCA, LCX-provoked spasm occurred significantly less than spasm in the other vessels and less than 70% patients had multiple spasms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complications of Pharmacological Spasm Provocation Tests

As pharmacological spasm provocation tests, acetylcholine (ACh) [1-3] and ergonovine (ER) [4,5] are employed in the cardiac catheterization laboratory. However, we often encounter the major and minor complications during performing these procedures. As a diagnostic tool, we should perform spasm provocation tests more safely without major complications. Multiple and proximal spasm documented by ...

متن کامل

Failure of intravascular ultrasound to identify the site of recurrent focal coronary spasm during stenting.

Focal coronary spasm is often associated with an area of mural plaque disease. This report describes a patient with recurrent severe coronary spasm unresponsive to medical treatment. Coronary arteriography and intravascular ultrasound identified a candidate area of minor coronary atheromatous disease but ergonovine provocation testing showed the spastic coronary segment to be distal to and dist...

متن کامل

Induction of coronary artery spasm by a direct local action of ergonovine.

To investigate whether ergonovine acts directly on coronary arteries or via remote neurohumoral reflexes, we administered small titrated increments of intracoronary ergonovine up to a maximum cumulative dose of 50 micrograms to 15 patients. In six patients with variant angina (group 1), ischemic electrocardiographic ST changes, angina, and localized coronary spasm (local coronary diameter reduc...

متن کامل

Long lasting spasticity in controlled vasospastic angina.

OBJECTIVE To evaluate changes in coronary artery spasticity in patients with vasospastic angina who had been stable for years under continuous drug treatment. METHODS Follow up coronary angiography was performed under intracoronary ergonovine provocation in 27 well controlled patients with vasospastic angina and no organic stenosis; the tests were done > 24 months after the initial coronary a...

متن کامل

Clinical usefulness, angiographic characteristics, and safety evaluation of intracoronary acetylcholine provocation testing among 921 consecutive white patients with unobstructed coronary arteries.

BACKGROUND Coronary spasm can cause myocardial ischemia and angina in patients with and those without obstructive coronary artery disease. However, provocation tests using intracoronary acetylcholine administration are rarely performed in clinical routine in the United States and Europe. Thus, we assessed the clinical usefulness, angiographic characteristics, and safety of intracoronary acetylc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 81 6  شماره 

صفحات  -

تاریخ انتشار 2017