A comparison of 3T and 7T in the detection of small parenchymal veins within MS lesions.

نویسندگان

  • Emma C Tallantyre
  • Paul S Morgan
  • Jennifer E Dixon
  • Ali Al-Radaideh
  • Matthew J Brookes
  • Nikos Evangelou
  • Peter G Morris
چکیده

OBJECTIVE Histologic examination of multiple sclerosis (MS) brain lesions reveals heterogeneity including the presence or absence of a central blood vessel. Recent work has shown that T2* weighted magnetic resonance imaging at 7T allows the identification of small parenchymal veins within MS lesions. The aims of this study were (1) to compare whether a comparable sequence at 3T was also capable of demonstrating parenchymal veins within MS brain lesions, and (2) to investigate the potential of 7T T2* weighted imaging to differentiate between MS white matter lesions and age-related vascular lesions seen in controls. MATERIALS AND METHODS Seven patients with demyelinating brain disease and 7 healthy volunteers were scanned at 3T and 7T. Fluid attenuated inversion recovery (FLAIR) images acquired at 3T were used to identify each brain lesion in each patient. A comparison of images from both field strengths was then made to determine whether white matter lesions seen in 3T FLAIR images could be identified in T2*-weighted images, and whether a central vein could be detected. RESULTS A total of 358 brain lesions were identified in the brains of the 7 patients using 3T FLAIR images. The 3T T2* sequence detected 89% of FLAIR lesions compared with 94% using the 7T T2* sequence (P = 0.0002). A central vessel could be identified in 45% of visible lesions using 3T T2* and 87% of visible lesions using 7T T2* (P < 0.0001). Using 7T T2* imaging, a central vein was evident in only 8% of the discrete white matter lesions found in the brains of healthy volunteers. DISCUSSION This study suggests that ultra high field imaging is advantageous in demonstrating detailed structural anatomy of MS lesions. 7T T2* imaging can be used in the future to investigate the pathogenesis of MS lesions. The potential for ultra high field imaging to discriminate between MS white matter lesions and microangiopathic lesions warrants further investigation as this would represent a clinically useful application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing 3T and 7T in the detection of small parenchymal blood vessels in MS lesions

Introduction: Post mortem studies of white matter (WM) demyelination in multiple sclerosis (MS) suggest that WM lesions are associated with small parenchymal blood vessels, supporting a hypothesis that formation of an MS lesion depends on the entry of inflammatory cells from the systemic circulation into brain parenchyma. However, the notion that every MS plaque shares this common mechanism has...

متن کامل

Optimisation of 3 T and 7 T T2-weighted MRI for the detection of small parenchymal veins in MS lesions

INTRODUCTION White-matter (WM) MS lesions are visible on MRI scans at conventional field strength and so MR is often used to diagnose and monitor patient progression. However, the poor correlation between MR findings and patient symptoms highlights the need to advance the study of these lesions in vivo. In particular, there is considerable interest in the heterogeneity of WM lesions. Post-morte...

متن کامل

7T MRI in natalizumab-associated PML and ongoing MS disease activity

OBJECTIVE To assess the ability of ultra-high-field MRI to distinguish early progressive multifocal leukoencephalopathy (PML) from multiple sclerosis (MS) lesions in a rare case of simultaneous presentation of natalizumab-associated PML and ongoing MS activity. METHODS Advanced neuroimaging including 1.5T, 3T, and 7T MRI with a spatial resolution of up to 0.08 mm(3) was performed. RESULTS 7...

متن کامل

Echo-Time and Field Strength Dependence of BOLD Reactivity in Veins and Parenchyma Using Flow-Normalized Hypercapnic Manipulation

While the BOLD (Blood Oxygenation Level Dependent) contrast mechanism has demonstrated excellent sensitivity to neuronal activation, its specificity with regards to differentiating vascular and parenchymal responses has been an area of ongoing concern. By inducing a global increase in Cerebral Blood Flow (CBF), we examined the effect of magnetic field strength and echo-time (TE) on the gradient...

متن کامل

Evaluation the FLAIR Sensitivity and DWI Post-inject in Comparison with Delayed Enhancement T1w for Better Detection of Active MS Lesions

Background: Multiple sclerosis (MS) is a chronic, typically progressive and most common autoimmune disease which damaged the central nervous system. According to the reports in 2008, this disorder has affected 2 and 2.5 million people globally. While the reason is not clear, proposed causes for this include immunologic, environmental, infectious and genetic factors, and sexuality. MS can cause ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative radiology

دوره 44 9  شماره 

صفحات  -

تاریخ انتشار 2009