Preservation of atrioventricular nodal conduction during radiofrequency current catheter ablation of midseptal accessory pathways.
نویسندگان
چکیده
BACKGROUND Septal accessory atrioventricular (AV) pathways may be located in close vicinity of the His bundle-AV nodal conduction system. Attempts at surgical or electrical interruption of these pathways may therefore result in impairment of normal AV conduction. This study focuses on a subset of septal pathways with an atrial insertion located inside the triangle of Koch. In this study, they were called "midseptal." METHODS AND RESULTS Six patients with a midseptal accessory pathway (mean +/- SD age, 40 +/- 12 years; five with Wolff-Parkinson-White syndrome and one with a concealed accessory pathway) underwent attempts at ablation of their pathway using 500-kHz radiofrequency current applied to the atrial insertion of the accessory connection. Guided by the recording of accessory pathway activation potentials, the ablation catheter was positioned in all patients in an area bounded anteriorly by the tip electrode of the His bundle catheter and posteriorly by the coronary sinus ostium. All pathways were successfully ablated without the induction of complete heart block. First-degree AV conduction block occurred in one patient in whom a concealed accessory connection was located closer to the AV node than to the coronary sinus ostium. CONCLUSIONS Radiofrequency current catheter ablation may be used effectively for midseptal accessory pathways and should be preferred in experienced centers as a safe alternative to surgical therapy.
منابع مشابه
Conduction During Radiofrequency Current Catheter Ablation of Midseptal Accessory Pathways
Background. Septal accessory atrioventricular (AV) pathways may be located in close vicinity of the His bundle-AV nodal conduction system. Attempts at surgical or electrical interruption of these pathways may therefore result in impairment of normal AV conduction. This study focuses on a subset of septal pathways with an atrial insertion located inside the triangle of Koch. In this study, they ...
متن کاملRadiofrequency ablation for WPW syndrome with monitoring the local electrogram at the ablation site.
Catheter ablation for septal accessory pathways is occasionally associated with complications, such as atrioventricular block, since the septal region is a complex anatomical structure containing the atrioventricular conduction system. Therefore, we designed a signal separator composed of an inductance-capacitance network with which the local electrogram at the ablation site could be continuous...
متن کاملCommentary: An Unusual Case of Leadless Pacemaker Implantation in a Patient with Wolff–Parkinson-White Syndrome: Just Because We Can, Does That Mean That We Should?
In the case presented by Drs. Tanaka-Esposito and Cantillon, a patient deemed to be at risk of developing unpredictable atrioventricular (AV) block based on electrophysiology findings and a catheter ablation procedure is chosen for the implantation of a leadless pacemaker that will provide permanent, prophylactic ventricular pacing. Briefly, this case involved a patient with a midseptal accesso...
متن کاملElectrocardiographic characteristics and catheter ablation of parahissian accessory pathways.
BACKGROUND Accessory pathways may be located in close proximity to the His bundle, resulting in a high risk of heart block during attempted surgical or electrical interruption of these pathways. This study reports the prevalence, ECG characteristics, and results of catheter ablation of parahissian accessory pathways. They were defined on the basis of both the presence of a high amplitude (> 0.1...
متن کاملCatheter cryoablation of cardiac arrhythmias.
PURPOSE OF REVIEW The purpose of the review is to provide an update on the safety and efficacy of catheter cryoablation. RECENT FINDINGS Catheter cryoablation is a safe and clinically effective method for ablation of atrioventricular nodal reentrant supraventricular tachycardia. Although the acute procedural success rate of catheter cryoablation for this arrhythmia may be slightly lower than ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 86 6 شماره
صفحات -
تاریخ انتشار 1992