Enzyme immunoassay for gentamicin.
نویسندگان
چکیده
We describe a gentamicin assay in which a peroxidase-gentamicin conjugate competes with gentamicin for binding to a gentamicin antibody adsorbed to a polystyrene solid phase. The assay can be completed in 30 min and requires 50 microliter of diluted serum. The precision and accuracy are equivalent to that of a radioimmunoassay technique and the reagents are stable for several months.
منابع مشابه
Rapid, reproducible enzyme immunoassay for gentamicin.
An enzyme immunoassay for gentamicin utilizing glucose-6-phosphate dehydrogenase was compared to the radioimmunoassay. The enzyme immunoassay for gentamicin was accurate, specific, and easily performed. It offers an ulternative method to assay aminoglycosides and could be used in institutions using enzyme immunoassay to assay other drugs.
متن کاملPotential liabilities of gentamicin homogeneous enzyme immunoassay.
We report two potential liabilities of the homogeneous enzyme immunoassay for the determination of serum gentamicin. One is a considerable loss of precision and accuracy at the ends of the calibration curve, and the other is an apparent loss of gentamicin with storage at -60 degrees C.
متن کاملEnzyme immunoassay of gentamicin with use of a centrifugal analyzer.
Gentamicin was determined in serum by the homogeneous enzyme immunoassay system (EMIT) adapted to the Multistat centrifugal analyzer. The standard curve can be extended to 16 mg/L; however, poor precision is obtained at concentrations greater than 10 mg/L because a small difference in change in absorbance there will produce a significant variation in gentamicin concentration. For example, the w...
متن کاملComparison of enzyme-multiplied immunoassay technique with fluorescence polarization immunoassay for determination of gentamicin and tobramycin levels in serum.
We assayed serum gentamicin and tobramycin specimens by the enzyme multiplied immunoassay technique (Syva EMIT) and the fluorescence polarization immunoassay (Abbott TDx). When interassay and intraassay control samples were evaluated, both methods gave an overall coefficient of variation of less than +/- 10%. Using patient serum samples, we obtained excellent correlation with both methods in th...
متن کاملNon-equilibrium enzyme immunoassay of gentamicin.
We describe a fast, accurate non-equilibrium enzyme immunoassay for serum gentamicin. With use of isokinetic conditions an assay takes a total of 12 min, including regeneration of the immunosorbent. The coefficient of correlation between the present method and conventional microbiological assays was 0.98.
متن کاملComparison of radioimmunoassay and enzyme immunoassay methods in determining gentamicin pharmacokinetic parameters and dosages.
Radioimmunoassay and enzyme immunoassay methods for analysis of serum gentamicin levels have been shown to be comparable. The purpose of this study was to determine if serum concentration-time data from the same patient assayed by radioimmunoassay and enzyme immunoassay would provide the same estimates for half-life, elimination rate constant, distribution volume, drug clearance, and gentamicin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 24 11 شماره
صفحات -
تاریخ انتشار 1978