Comparative multivariate analyses of transient otoacoustic emissions and distorsion products in normal and impaired hearing.

نویسندگان

  • Mirela Cristina Stamate
  • Nicolae Todor
  • Marcel Cosgarea
چکیده

BACKGROUND AND AIM The clinical utility of otoacoustic emissions as a noninvasive objective test of cochlear function has been long studied. Both transient otoacoustic emissions and distorsion products can be used to identify hearing loss, but to what extent they can be used as predictors for hearing loss is still debated. Most studies agree that multivariate analyses have better test performances than univariate analyses. The aim of the study was to determine transient otoacoustic emissions and distorsion products performance in identifying normal and impaired hearing loss, using the pure tone audiogram as a gold standard procedure and different multivariate statistical approaches. METHODS The study included 105 adult subjects with normal hearing and hearing loss who underwent the same test battery: pure-tone audiometry, tympanometry, otoacoustic emission tests. We chose to use the logistic regression as a multivariate statistical technique. Three logistic regression models were developed to characterize the relations between different risk factors (age, sex, tinnitus, demographic features, cochlear status defined by otoacoustic emissions) and hearing status defined by pure-tone audiometry. The multivariate analyses allow the calculation of the logistic score, which is a combination of the inputs, weighted by coefficients, calculated within the analyses. The accuracy of each model was assessed using receiver operating characteristics curve analysis. We used the logistic score to generate receivers operating curves and to estimate the areas under the curves in order to compare different multivariate analyses. RESULTS We compared the performance of each otoacoustic emission (transient, distorsion product) using three different multivariate analyses for each ear, when multi-frequency gold standards were used. We demonstrated that all multivariate analyses provided high values of the area under the curve proving the performance of the otoacoustic emissions. Each otoacoustic emission test presented high values of area under the curve, suggesting that implementing a multivariate approach to evaluate the performances of each otoacoustic emission test would serve to increase the accuracy in identifying the normal and impaired ears. We encountered the highest area under the curve value for the combined multivariate analysis suggesting that both otoacoustic emission tests should be used in assessing hearing status. Our multivariate analyses revealed that age is a constant predictor factor of the auditory status for both ears, but the presence of tinnitus was the most important predictor for the hearing level, only for the left ear. Age presented similar coefficients, but tinnitus coefficients, by their high value, produced the highest variations of the logistic scores, only for the left ear group, thus increasing the risk of hearing loss. We did not find gender differences between ears for any otoacoustic emission tests, but studies still debate this question as the results are contradictory. Neither gender, nor environment origin had any predictive value for the hearing status, according to the results of our study. CONCLUSION Like any other audiological test, using otoacoustic emissions to identify hearing loss is not without error. Even when applying multivariate analysis, perfect test performance is never achieved. Although most studies demonstrated the benefit of using the multivariate analysis, it has not been incorporated into clinical decisions maybe because of the idiosyncratic nature of multivariate solutions or because of the lack of the validation studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The relationship between ultra-high frequency thresholds and transient evoked otoacoustic emissions in adults with tinnitus

  Background: The possible role of cochlear function in tinnitus generation is still a matter of debate. To assess the role of outer hair cell dysfunction in tinnitus and its possible relationship with ultra-high frequency (UHF) hearing sensitivity, transient evoked otoacoustic emissions (TEOAE) and UHF hearing thresholds were investigated in normal hearing individuals with and withou...

متن کامل

Evaluation of Distortion and Transient Evoked Otoacoustic Emission in Tinnitus Patients with Normal Hearing

Introduction: Tinnitus is a perception of sound without external source. The exact etiology of tinnitus is not fully understood, although some researchers believe that the condition usually starts in the cochlea. The aim of this study was to determine the potential contribution of outer hair cell dysfunction to chronic tinnitus, by application of Distortion-Product Evoked Otoacoustic Emission (...

متن کامل

Investigation of the results of infant hearing screening test with transient evoked otoacoustic emissions in Moradi Hospital of Rafsanjan, Iran, in 2014

Background: Congenital hearing loss delays many aspects of a child's development, including speech and socio-cognitive development. The aim of this study was determine the results of infant hearing screening with transient evoked otoacoustic emission (TEOAE) in Moradi Hospital, Rafsanjan, Iran: 2014. Materials and Methods: In this descriptive cross-sectional study from 6017 infants born in Nik...

متن کامل

Otoacoustic Emissions in Sudden Sensorineural Hearing Loss: Changes of Measures with Treatment

Introduction: To identify changes in OAEs parameters in treatment course of idiopathic sudden sensorineural hearing loss (iSSNHL). Materials and Methods: In aprospective studyfromAugust 2005 to January 2009, 26 patients with iSSNHL underwent conventional audiometry/tympanometry and two types of OAEs (TEOAEs and DPOAEs) before and after the completion of standard drug therapy.The changes in p...

متن کامل

Post-processing analysis of transient-evoked otoacoustic emissions to detect 4 kHz-notch hearing impairment – a pilot study

BACKGROUND To identify a parameter to distinguish normal hearing from hearing impairment in the early stages. The parameter was obtained from transient-evoked otoacoustic emissions (TEOAEs), overcoming the limitations of the usually adopted waveform descriptive parameters which may fail in standard clinical screenings. MATERIAL/METHODS Audiometric examinations and TEOAE analysis were conducte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clujul medical

دوره 88 4  شماره 

صفحات  -

تاریخ انتشار 2015