Comparison of Breast Doses for Digital Tomosynthesis Estimated from Patient Exposures and Using PMMA Breast Phantoms

نویسندگان

  • David R. Dance
  • Celia J. Strudley
  • Kenneth C. Young
  • Jennifer M. Oduko
  • Patsy J. Whelehan
  • E. H. Lindsay Mungutroy
چکیده

A proposed European protocol for dosimetry in digital breast tomosynthesis (DBT) has been applied to estimate the average glandular breast dose (AGD) for two different DBT units. AGD was measured for the examination of series of women and for breast-simulating polymethyl methacrylate (PMMA) phantoms, thus assessing the suitability of the phantoms used for dosimetry in 2D mammography for DBT dosimetry. For the first system the mean values of the AGD for breast thicknesses of 21mm, 53mm and 90mm, were 1.21±0.06 (2 s.e.m), 2.12±0.07 and 4.90±0.11 mGy respectively. The corresponding values for the equivalent PMMA thicknesses of 20mm, 45mm and 70mm were 0.92, 2.08 and 4.65 mGy respectively. Similar agreement was found for the second system. It is concluded that the use of standard PMMA phantoms of appropriate thicknesses (as used for 2D dosimetry) to simulate the breast in DBT provides a reasonable estimate of the AGD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU

Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...

متن کامل

Cumulative radiation exposure dose of diagnostic imaging studies in breast cancer patients

Background: Breast cancer is a common disease in radiation oncology. We evaluated the radiation dose received by breast cancer patients, an often-neglected concern. Materials and Methods: The total effective radiation dose in 101 breast cancer patients was calculated by summing the effective doses of individual diagnostic imaging tests from the first hospital visit to the initiation of radiothe...

متن کامل

Power Spectrum Analysis of an Anthropomorphic Breast Phantom Compared to Patient Data in 2D Digital Mammography and Breast Tomosynthesis

Digital breast tomosynthesis (DBT) images of a novel anthropomorphic breast phantom (UPenn phantom) acquired on two breast tomosynthesis systems were analyzed in terms of their power spectra (PS). The β and κ power law coefficients were estimated from 2D planar, tomosynthesis projection images and reconstructed planes. These data were compared to the PS characteristics as retrieved from a group...

متن کامل

The Effect of Breast Phantom Material on the Dose Distribution in AccuBoost Brachytherapy

Introduction: Long-term teletherapy program is not suitable for old and working patients and those living in areas where little access to primary health care is available. Accelerated partial breast irradiation (APBI) using high dose rate (HDR) brachytherapy is an appropriate alternative for these patients due to its limited number of fractions. The AccuBoost is a system for delivering APBI. Th...

متن کامل

A Comparison of Reconstruction Algorithms Regarding Exposure Dose Reductions during Digital Breast Tomosynthesis

This study compared reconstruction algorithms [filtered back projection (FBP) and simultaneous iterative reconstruction technique (SIRT)] with respect to radiation doses and image quality and suggested the possibility of decreasing the exposure dose in digital breast tomosynthesis (DBT). These two existing algorithms were implemented using a DBT system and experimentally evaluated using contras...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -