Analysis of left ventricular volumes and function: a multicenter comparison of cardiac magnetic resonance imaging, cine ventriculography, and unenhanced and contrast-enhanced two-dimensional and three-dimensional echocardiography.
نویسندگان
چکیده
BACKGROUND Contrast echocardiography improves accuracy and reduces interreader variability on left ventricular (LV) functional analyses in the setting of two-dimensional (2D) echocardiography. The need for contrast imaging using three-dimensional (3D) echocardiography is less defined. The aim of this multicenter study was to define the accuracy and interreader agreement of unenhanced and contrast-enhanced 2D and 3D echocardiography for the assessment of LV volumes and ejection fraction (EF). METHODS A multicenter, open-label study was conducted including 63 patients, using intrasubject comparisons to assess the agreement of unenhanced and contrast-enhanced 2D and 3D echocardiography as well as calibrated biplane cine ventriculography with cardiac magnetic resonance for the determination of LV volumes and EF. Each of the imaging techniques used to define LV function was assessed by two independent, off-site readers unaware of the results of the other imaging techniques. RESULTS LV end-systolic and end-diastolic volumes were underestimated by 2D and 3D unenhanced echocardiography compared with cardiac magnetic resonance. Contrast enhancement resulted in similar significant increases in LV volumes on 2D and 3D echocardiography. The mean percentage of interreader variability for LV EF was reduced from 14.3% (95% confidence interval [CI], 11.7%-16.8%) for unenhanced 2D echocardiography and 14.3% (95% CI, 9.7%-18.9%) for unenhanced 3D echocardiography to 8.0% (95% CI, 6.3%-9.7%; P < .001) for contrast-enhanced 2D echocardiography and 7.4% (95% CI, 5.7%-9.1%; P < .01) for contrast-enhanced 3D echocardiography and thus to a similar level as for cardiac magnetic resonance (7.9%; 95% CI, 5.4%-10.5%). A similar effect was observed for interreader variability for LV volumes. CONCLUSIONS Contrast administration on 3D echocardiography results in improved determination of LV volumes and reduced interreader variability. The use of 3D echocardiography requires contrast application as much as 2D echocardiography to reduce interreader variability for volumes and EF.
منابع مشابه
Dysglycemia and cardiovascular risk.
1. Hoffmann R, von Bardeleben S, Kasprzak JD, et al. Analysis of regional left ventricular function by cineventriculography, cardiac magnetic resonance imaging, and unenhanced and contrast-enhanced echocardiography: a multicenter comparison of methods. J Am Coll Cardiol 2006; 47:121–8. 2. Hoffmann R, von Bardeleben S, ten Cate F, et al. Assessment of systolic left ventricular function: a multi-...
متن کاملAccuracy of cardiac CT, radionucleotide and invasive ventriculography, two- and three-dimensional echocardiography, and SPECT for left and right ventricular ejection fraction compared with cardiac MRI: a meta-analysis.
AIMS Left ventricular ejection fraction (LVEF) and right ventricular ejection fraction (RVEF) are important tools in clinical decision-making. We hypothesized that two-dimensional echocardiography (2DE), three-dimensional echocardiography (3DE), radionucleotide ventriculography (RNV), cardiac computed tomography (CT), gated single-photon emission CT (SPECT), and invasive cardiac cine ventriculo...
متن کاملAnalysis of regional left ventricular function by cineventriculography, cardiac magnetic resonance imaging, and unenhanced and contrast-enhanced echocardiography: a multicenter comparison of methods.
OBJECTIVES To define the use of cineventriculography, cardiac magnetic resonance imaging (cMRI), and unenhanced and contrast-enhanced echocardiography for detection of left ventricular (LV) regional wall motion abnormalities (RWMA). BACKGROUND Detection of RWMA is integral to the evaluation of LV function. METHODS In 100 patients, cineventriculography and unenhanced and contrast-enhanced ec...
متن کاملAssessment of systolic left ventricular function: a multi-centre comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced and contrast-enhanced echocardiography.
AIMS To assess the agreement of left ventricular ejection fraction (LVEF) determinations from unenhanced echocardiography, contrast-enhanced echocardiography, magnetic resonance imaging (MRI), and cineventriculography as well as the inter-observer agreement for each method. METHODS AND RESULTS In 120 patients, with evenly distributed EF-groups (> 55, 35-55, < 35%), cineventriculography, unenh...
متن کاملRight ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease
Introduction: In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
دوره 27 3 شماره
صفحات -
تاریخ انتشار 2014