Three Dimensional Quantitative Coronary Angiography Can Detect Reliably Ischemic Coronary Lesions Based on Fractional Flow Reserve

نویسندگان

  • Woo-Young Chung
  • Byoung-Joo Choi
  • Seong-Hoon Lim
  • Yoshiki Matsuo
  • Ryan J Lennon
  • Rajiv Gulati
  • Gurpreet S Sandhu
  • David R Holmes
  • Charanjit S Rihal
  • Amir Lerman
چکیده

Conventional coronary angiography (CAG) has limitations in evaluating lesions producing ischemia. Three dimensional quantitative coronary angiography (3D-QCA) shows reconstructed images of CAG using computer based algorithm, the Cardio-op B system (Paieon Medical, Rosh Ha'ayin, Israel). The aim of this study was to evaluate whether 3D-QCA can reliably predict ischemia assessed by myocardial fractional flow reserve (FFR) < 0.80. 3D-QCA images were reconstructed from CAG which also were evaluated with FFR to assess ischemia. Minimal luminal diameter (MLD), percent diameter stenosis (%DS), minimal luminal area (MLA), and percent area stenosis (%AS) were obtained. The results of 3D-QCA and FFR were compared. A total of 266 patients was enrolled for the present study. FFR for all lesions ranged from 0.57 to 1.00 (0.85 ± 0.09). Measurement of MLD, %DS, MLA, and %AS all were significantly correlated with FFR (r = 0.569, 0609, 0.569, 0.670, respectively, all P < 0.001). In lesions with MLA < 4.0 mm(2), %AS of more than 65.5% had a 80% sensitivity and a 83% specificity to predict FFR < 0.80 (area under curve, AUC was 0.878). 3D-QCA can reliably predict coronary lesions producing ischemia and may be used to guide therapeutic approach for coronary artery disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fractional flow reserve from 3-dimensional quantitative coronary angiography: fresh light through an old window.

In this issue of JACC: Cardiovascular Interventions, Tu et al. (1) report on an initial validation study for a less-invasive approach to derive fractional flow reserve (FFR) based on the coronary angiogram. The investigators should be congratulated on developing an innovative means to expand the diagnostic value of angiography by including physiological ischemic assessment, potentially broadeni...

متن کامل

Advances in three-dimensional coronary imaging and computational fluid dynamics: is virtual fractional flow reserve more than just a pretty picture?

Percutaneous coronary intervention (PCI) has shown a high success rate in the treatment of coronary artery disease. The decision to perform PCI often relies on the cardiologist's visual interpretation of coronary lesions during angiography. This has inherent limitations, particularly due to the low resolution and two-dimensional nature of angiography. State-of-the-art modalities such as three-d...

متن کامل

Virtual fractional flow reserve from coronary angiography: modeling the significance of coronary lesions: results from the VIRTU-1 (VIRTUal Fractional Flow Reserve From Coronary Angiography) study.

OBJECTIVES The aim of this study was to develop a computer model that accurately predicts myocardial fractional flow reserve (FFR) from angiographic images alone, in patients with coronary artery disease. BACKGROUND Percutaneous coronary intervention (PCI) guided by FFR is superior to standard assessment alone. FFR-guided PCI results in improved clinical outcomes, a reduction in the number of...

متن کامل

Multicenter evaluation of dynamic three-dimensional whole-heart myocardial perfusion imaging for the detection of coronary artery disease defined by fractional flow reserve

Background Cardiac magnetic resonance (CMR) perfusion imaging yields high diagnostic accuracy for the detection of coronary artery disease (CAD) [1]. However, standard 2D multislice CMR perfusion techniques only provide limited coverage and hence prohibit computation of myocardial ischemic burden. Recently, two single-center 3D CMR perfusion studies have proven highly diagnostic for the detecti...

متن کامل

Noninvasive fractional flow reserve derived from coronary computed tomography angiography for identification of ischemic lesions: a systematic review and meta-analysis

Detection of coronary ischemic lesions by fractional flow reserve (FFR) has been established as the gold standard. In recent years, novel computer based methods have emerged and they can provide simulation of FFR using coronary artery images acquired from coronary computed tomography angiography (FFRCT). This meta-analysis aimed to evaluate diagnostic performance of FFRCT using FFR as the refer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2015