An alternative approach for detecting interferences in enzymatic acetaminophen assays.

نویسندگان

  • Johannes Zeidler
  • Peter A Kavsak
چکیده

We read with interest the recent description of yet another case of bilirubin-related positive interference in an enzymatic colorimetric assay for acetaminophen (1 ). As a remedy, these authors suggest measuring bilirubin before every acetaminophen assay and removing it by ultrafiltration when the bilirubin concentration is higher than the reported cutoffs for interference. An alternative and perhaps less costly approach would be to estimate an icteric index, an approximation of the bilirubin concentration based on an absorbance measurement, and to dilute the sample if the icteric index is high. This procedure stemmed from an incident within our laboratory program in which a physician questioned the validity of an acetaminophen result (Roche enzymatic assay) for a patient who had denied taking acetaminophen. In this case, we obtained 4 different samples from this patient (over 4 consecutive days) and measured both bilirubin and acetaminophen in the 4 undiluted samples [bilirubin range, 19.5–23.3 mg/dL (333–399 mol/L); acetaminophen range, 14 –18 g/mL (93–120 mol/L)] as well as in serial dilutions (1 volume in 2 and 1 volume in 4 with the therapeutic drug monitoring diluent). The mean (SD) recovery percentages for the bilirubin concentration after the 1-in-2 and 1-in-4 dilutions were 99% (1) and 98% (2), respectively, whereas for acetaminophen the recoveries were only 64% (3) and 38% (4) (Fig. 1). Thus, our experience with the Roche acetaminophen enzymatic assay has been that falsely increased acetaminophen results drop more than expected upon serial dilution, whereas bilirubin results follow the expected linear pattern. Importantly, we have also confirmed the linearity of this acetaminophen assay for samples with high acetaminophen concentrations that do not have this interference (2 ). These data add to the literature, which suggests that the enzymatic acetaminophen assays are susceptible to a chemical, rather than a spectrophotometric, interference in samples with high bilirubin concentrations (3 ). Also of note is our simple dilution protocol to detect the presence of a positive interference. For more accurate quantification of acetaminophen, there are interference-free methods [e.g., chromatography, mass spectrometry, enzyme-multiplied immunoassay technique (EMIT)] (4 ). Given that the presence of positive interference in such enzymatic assays can be quickly uncovered with the icteric index and a dilution protocol, any confirmatory testing can be performed with less urgency. This consideration is important, because the presence of measurable acetaminophen at any concentration can indicate harm, depending on the timing and many other factors (5 ). In view of the potential for harm, the possible presence of an interference warrants further investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid and specific quantification of ethylene glycol levels: adaptation of a commercial enzymatic assay to automated chemistry analyzers.

Ethylene glycol ingestion, accidental or intentional, can be a life-threatening emergency. Assays are not available from most clinical laboratories, and, thus, results often require many hours or days to obtain. Enzymatic assays, adaptable to automated chemistry analyzers, have been evaluated, but they have been plagued by analytic problems. With an alternative method of data analysis applied t...

متن کامل

False positive acetaminophen concentrations in icteric serum

INTRODUCTION Serum concentrations of acetaminophen are measured to predict the risk of hepatotoxicity in cases of acetaminophen overdose and to identify acetaminophen use in patients with acute liver injury without a known cause. The acetaminophen concentration determines if treatment with N-acetyl cysteine, the antidote for acetaminophen poisoning, is warranted. DESCRIPTION A 49-year-old wom...

متن کامل

Catecholamine interference in enzymatic creatinine assays.

BACKGROUND Enzymatic creatinine assays are routinely used in clinical laboratories to provide more accurate estimated glomerular filtration rates and to avoid a perceived lack of analytical specificity associated with picrate (Jaffe) methods. Negative interferences with the enzymatic creatinine assay, which we noted in several patients on dopamine or dobutamine, prompted our further investigati...

متن کامل

Urinary sampling for 5HIAA and metanephrines determination: revisiting the recommendations

CONTEXT Biogenic amines such as 5-hydroxy-indole acetic acid (5HIAA) the main metabolite of serotonin or metanephrines (catecholamines metabolites) are used as biomarkers of neuroendocrine tumours. OBJECTIVE To re-evaluate the recommendations for urinary sampling (preservatives, diet, drugs, etc.) as many of the reported analytical interferences supporting these recommendations are related to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 57 8  شماره 

صفحات  -

تاریخ انتشار 2011