Continuous Wave Doppler Echocardiographic Measurement of Prosthetic Valve Gradients

نویسندگان

  • Darryl J. Burstow
  • Guy S. Reeder
  • James B. Seward
چکیده

Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63+13 years) with 42 prosthetic valves (20 aortic, 20 mitral, one tricuspid, and one pulmonary) were studied. Catheter gradients were obtained using a dual-catheter technique. The simultaneous

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study.

Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63 +/- 13 years) with 42 prosthetic valve...

متن کامل

Validation of continuous-wave Doppler echocardiographic measurements of mitral and tricuspid prosthetic valve gradients: a simultaneous Doppler-catheter study.

For patients with stenotic native valves, the modified Bernoulli equation (delta P = 4V2) may be applied to Doppler-measured transvalvular velocities to yield an accurate estimate of transvalvular gradients. Although it would be useful if the same approach could be used for those with stenotic prosthetic valves, no previous study has validated the Doppler technique in this setting. We therefore...

متن کامل

Doppler echocardiographic evaluation of prosthetic valve function.

Owing to its versatile, non-invasive, radiation-free, and low cost nature, Doppler echocardiography is undoubtedly the method of choice to evaluate prosthetic valve function. This evaluation follows the same principles used for the evaluation of native valves, with some important specifics and caveats described in this article. A complete echocardiography includes two dimensional imaging of the...

متن کامل

Continuous-wave Doppler echocardiographic assessment of severity of calcific aortic stenosis: a simultaneous Doppler-catheter correlative study in 100 adult patients.

Studies of the correlation of aortic valve gradient determined by continuous-wave Doppler echocardiography and that determined at catheterization have, to date, involved young patients and nonsimultaneous measurements. We therefore obtained simultaneous Doppler echocardiographic and catheter measurements of pressure gradient in 100 consecutive adults (mean age 69, range 50 to 89 years). In 63 p...

متن کامل

Delayed rupture of right coronary artery after directional atherectomy for bail-out.

nique (Table I). The differences of 2 mm Hg and 1 mm Hg in peak and mean gradients, respectively, were not considered to be of clinical significance. Subsequent cardiac catheterization performed 48 hours later confirmed a mean mitral prosthetic diastolic gradient of 13 mm Hg. The calculated mitral valve area was 0.7 cm2. The excised mitral valve prosthesis revealed extensively thickened and cal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005