Abutment load transfer by removable partial denture obturator frameworks in different acquired maxillary defects.

نویسندگان

  • K M Lyons
  • J Beumer
  • A A Caputo
چکیده

STATEMENT OF PROBLEM Excessive stress on abutment teeth adjacent to a maxillary resection defect during loading of partial denture obturator frameworks may shorten the life of the teeth. PURPOSE The aim of this study was to photoelastically compare the forces exerted on the supporting structures of abutment teeth in 3 differently sized surgical resections with removable partial denture designs used to restore such maxillectomy defects. MATERIAL AND METHODS Composite photoelastic models were constructed of a human maxilla that had undergone each of 3 maxillectomies: partial, radical, and radical involving the contralateral premaxilla. The abutment teeth included all remaining anterior teeth, the first premolar, and second molar, except the radical maxillectomy, which included the contralateral premaxilla where all remaining teeth were used as abutment teeth. All abutment teeth were restored with complete metal crowns, and removable partial denture frameworks were fabricated. Loading zones were selected according to the resection, and a 10-lb load was applied at each load point. The resulting stresses were observed and recorded photographically in a circular polariscope. The 2 teeth adjacent to the resection were then splinted, and the loading regimens were repeated. RESULTS Without splinting, loads closer to the defect produced lingual tipping of the teeth adjacent to the resection and a mesial tipping tendency of the second molar. The tipping effects were greatest in the model with the largest resection. Splinting reduced tipping of the teeth adjacent to the resection and produced more uniform stress around these 2 abutment tooth roots for all of the models. CONCLUSION The results of this in vitro study suggest that splinting the 2 teeth adjacent to a resection defect improves stress distribution around the roots during loading. This could increase the clinical life of the abutment teeth.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stress Distribution in Natural Tooth and Implant Supported Removable Partial Denture with Different Attachment Types: A Photoelastic Analysis

Background and Aim: Different attachment designs have been developed to connect implant to natural teeth in partial dentures; however, adequate studies have not been performed to determine stress distribution patterns in these designs. The present study aimed to assess stress distribution patterns in natural tooth and implant supported removable partial denture with different attachment designs...

متن کامل

Rehabilitation of Patient with Maxillary Defect Using Polyacetal Resin Obturator Prostheses: A Case Report

Polyacetal resin is well known material in medical field for various applications such as for artificial heart valves and artificial hip joints. In dentistry the material among its other applications, is used for removable partial dentures. The article presents rehabilitation of a patient with maxillary defect using polyacetal resin obturator prostheses. The patient was rehabilitated 5 years ag...

متن کامل

Partial removable prosthesis in a patient with unilateral maxillectomy: A case report

BACKGROUND AND AIM: Maxillofacial defects due to malignant or benign tumors or congenital defects often result in complications such as the impairment of facial aesthetic, mastication, speech, and swallowing. Remedy of these defects, especially in a dentate patient is an important challenge in prosthodontics. Maxillectomy can lead to severe anatomical changes f...

متن کامل

Comparison between Acetal Resin and Cobalt-chromium Removable Partial Denture Clasps: Effect on Abutment Teeth

Fabricating an esthetically pleasing removable partial denture while avoiding the unsightly display associated with conventional clasp assemblies presented a challenge to dentists. Among other techniques, this could be done using acetal resin clasps as simple and effective means of improving removable partial denture esthetics.1 Patients often cite lack of retention and poor esthetics as reason...

متن کامل

[A clinical report of application of implant-supported fixed partial denture with a removable gingival veneer to a patient who has severe resorption of maxillary anterior ridge].

PATIENT A 39-year-old female patient was admitted with mobility of maxillary anterior fixed partial denture. She was diagnosed as severe chronic periodontitis of abutment teeth of the denture, left alveolus cleft, and anterior/posterior crossbites. The crossbites were improved by prosthetic approach using an implant-supported fixed partial denture with a removable gingival veneer at the anterio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 94 3  شماره 

صفحات  -

تاریخ انتشار 2005