Initial tension and anterior load-displacement behavior of high-stiffness anterior cruciate ligament graft constructs.
نویسندگان
چکیده
BACKGROUND Because the tension that exists in an anterior cruciate ligament graft when the knee is unloaded (the initial tension) affects the surgical outcome and because high initial tension has a number of adverse consequences, the primary purpose of this study was to determine quantitatively how much less initial tension was required for a high-stiffness construct than for a low-stiffness construct. A secondary purpose was to determine how the stiffness of the graft construct affects the anterior load-displacement behavior of the knee from 0 degrees to 90 degrees of flexion. METHODS Anterior-posterior load-displacement was measured in each of ten intact cadaveric knee specimens, the anterior cruciate ligament was excised, and the anterior cruciate ligament was reconstructed with a double-loop bovine tendon graft. Graft constructs of different stiffness were created with use of six springs, ranging in stiffness from 25 to 275 N/mm to simulate the fixation stiffness. After adjusting the initial tension of the graft so that the anterior-posterior laxity of the reconstructed knee matched that of the intact knee, the 0-N posterior limit and the 225-N anterior limit were measured at 0 degrees, 30 degrees, 60 degrees, and 90 degrees of flexion. RESULTS The highest stiffness fixation (275 N/mm) required an average of 73 N of initial tension, which was more than three times less than the average of 242 N of initial tension required by the lowest stiffness fixation (25 N/mm). The 225-N anterior limit was overconstrained an average of 1.0 mm with the highest stiffness fixation (275 N/mm), which was 3.6 mm less than the overconstraint with the lowest stiffness fixation (25 N/mm). Likewise, the posterior limit was overconstrained an average of 2.6 mm with the highest stiffness fixation (275 N/mm), which was 3.8 mm less than the overconstraint with the lowest stiffness fixation (25 N/mm). CONCLUSIONS The initial tension for a high-stiffness graft construct is more than three times less than that for a low-stiffness construct. The initial tension for a high-stiffness graft construct better restores both the 225-N anterior limit and the 0-N posterior limit to normal than the initial tension for a low-stiffness graft construct over the range of flexion from 0 degrees to 90 degrees.
منابع مشابه
How the fixation method stiffness and initial tension affect anterior load-displacement of the knee and tension in anterior cruciate ligament grafts: a study in cadaveric knees using a double-loop hamstrings graft.
There were two objectives to this study. The first was to investigate the relationship of graft fixation stiffness and graft initial tension on the anterior load-displacement behavior of knees reconstructed with a double-loop hamstrings tendon graft. The second was to determine the corresponding graft tensions at 225 N of anterior force applied to the knee. To satisfy these objectives, the ante...
متن کاملDoes a tensioning device pinned to the tibia improve knee anterior-posterior load-displacement compared to manual tensioning of the graft following anterior cruciate ligament reconstruction? A cadaveric study of two tibial fixation devices.
Devices that are pinned to the tibia to tension an anterior cruciate ligament (ACL) graft produce joint reaction loads that in turn can affect the maintenance of graft initial tension after tibial fixation and hence knee anterior-posterior (AP) load-displacement. However, the effect of these devices on AP load-displacement is unknown. Our objectives were to determine whether tensioning by devic...
متن کاملTibial fixation of anterior cruciate ligament allograft tendons: comparison of 1-, 2-, and 4-stranded constructs.
BACKGROUND In sum, 1-, 2-, and 4-stranded allografts are used for soft tissue anterior cruciate ligament reconstruction; however, the fixation properties of fixation devices are not well assessed. HYPOTHESIS There are no differences in the biomechanical characteristics of 1 (Achilles)-, 2 (posterior tibialis)-, and 4 (semitendinosus)-stranded allograft tibial fixation. STUDY DESIGN Controll...
متن کاملContact pressure and tension in anterior cruciate ligament grafts subjected to roof impingement during passive extension.
Contact between an anterior cruciate ligament graft and the intercondylar roof has been termed roof impingement. Grafts with impingement sustain permanent damage, and if the injury is extensive enough, then the graft may fail, causing recurrent instability. This study evaluated two mechanical factors that could be responsible for the graft injury associated with roof impingement: an increase in...
متن کاملA Biomechanical Comparison of 4-Strand and 5-Strand Anterior Cruciate Ligament Graft Constructs
Hamstring tendon autografts are used for reconstruction of the anterior cruciate ligament. This study tested the hypothesis that a 5-strand hamstring autograft construct is superior in strength to a 4-strand construct. Four-strand and 5-strand tendon grafts constructs were prepared from ovine flexor tendons and then tested in a uniaxial electromechanical load system with suspensory fixation. Th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 86-A 8 شماره
صفحات -
تاریخ انتشار 2004