Adenosine Stress High-pitch 128-slice Dual Source Myocardial Computed Tomography Perfusion For Imaging Of Reversible Myocardial Ischemia: Comparison with Magnetic Resonance Imaging Feuchtner et al: Myocardial Perfusion Imaging with CT
نویسندگان
چکیده
Background Coronary computed tomography angiography (CTA) enables accurate anatomic evaluation of coronary artery stenosis, however lacking information about hemodynamical significance. The aim of this study was to evaluate 128-slice myocardial CT perfusion (CTP) imaging with adenosine stress using a high-pitch mode, in comparison with cardiac magnetic resonance imaging (CMR). Methods and Results 39 patients with intermediate-to-high coronary risk profile underwent adenosine stress 128-slice dual source CTP (128x0.6mm, 0.28s). Among those, 30 patients (64±10y, 6% females) also underwent adenosine stress CMR (1.5T). The 2-steps CTP protocol consisted of: 1) Adenosine stress-CTP using a high-pitch factor (3.4) ECG-synchronized spiral mode and 2) rest-CTP/coronary-CTA using either high-pitch (HR<63bpm) or prospective ECGtriggering (HR>63bpm). Results were compared to CMR and to invasive angiography (IA) in 25 patients. The performance of stress-CTP for detection of myocardial perfusion defects compared to CMR was: sens. 96%, spec. 88%, PPV 93%, NPV 94% (per vessel), and sens. 78%, spec. 87%, PPV 83%, NPV 84% (per segment). The accuracy of stress-CTP for imaging of reversible ischemia compared to CMR was: sens 95%, spec 96%, PPV 95%, NPV 96% (per vessel). In 25 patients who underwent IA, the accuracy of CTA for detection of stenosis >70% was (per segment): sens. 96%, spec. 88%, PPV 67%, NPV 98.9%. The accuracy improved from 84% to 95% after adding stress CTP to CTA. Radiation exposure of the entire stress/rest CT protocol was only 2.5mSv. Conclusions Adenosine-induced stress 128-slice dual source high-pitch myocardial CTP allows for simultaneously assessment of reversible myocardial ischemia and coronary stenosis with good diagnostic accuracy as compared to CMR and IA, at a very low radiation exposure.
منابع مشابه
Adenosine stress high-pitch 128-slice dual-source myocardial computed tomography perfusion for imaging of reversible myocardial ischemia: comparison with magnetic resonance imaging.
BACKGROUND Coronary computed tomography angiography (CTA) enables accurate anatomic evaluation of coronary artery stenosis but lacks information about hemodynamic significance. The aim of this study was to evaluate 128-slice myocardial CT perfusion (CTP) imaging with adenosine stress using a high-pitch mode, in comparison with cardiac MRI (CMR). METHODS AND RESULTS Thirty-nine patients with i...
متن کاملStress and rest dynamic myocardial perfusion imaging by evaluation of complete time-attenuation curves with dual-source CT.
OBJECTIVES This study sought to describe a protocol for myocardial perfusion imaging using dipyridamole stress, with 128-slice dual-source computed tomography (CT), and to assess the ability of CT myocardial perfusion imaging (MPI) to detect abnormal flow reserve and infarction in comparison with nuclear MPI (NMPI). BACKGROUND CT MPI has not been previously described with the 128-slice dual-s...
متن کاملMyocardial ischemia evaluation with dual-source computed tomography: comparison with magnetic resonance imaging.
INTRODUCTION AND OBJECTIVES Computed tomography does not accurately determine which coronary lesions lead to myocardial ischemia and consequently further tests are required to evaluate ischemia induction. The aim of this study was to compare diagnostic accuracy between dual-energy computed tomography and magnetic resonance imaging in the assessment of myocardial perfusion and viability in patie...
متن کاملCovid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT
A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced...
متن کاملIncremental value of adenosine-induced stress myocardial perfusion imaging with dual-source CT at cardiac CT angiography.
PURPOSE First, to assess the feasibility of a protocol involving stress-induced perfusion evaluated at computed tomography (CT) combined with cardiac CT angiography in a single examination and second, to assess the incremental value of perfusion imaging over cardiac CT angiography in a dual-source technique for the detection of obstructive coronary artery disease (CAD) in a high-risk population...
متن کامل