HLA-B27 screening by flow cytometry.

نویسندگان

  • B Lingenfelter
  • T C Fuller
  • L Hartung
  • J Hunter
  • C Wittwer
چکیده

A flow cytometric assay for lymphocyte HLA-B27 expression using a two-color direct immunofluorescent assay was compared to traditional microlymphocytotoxicity testing on 209 clinical samples. For the flow cytometric assay, whole blood was mixed with a monoclonal anti-B27 conjugated to fluorescein-isothiocyanate (FITC) and anti-CD3 conjugated to phycoerythrin (PE). The samples were analyzed with flow cytometry by gating on CD3 positive events and anti-B27 staining intensity was evaluated as median channel fluorescence of the histogram peak. The median channel fluorescence was least with B27 negative and B7 negative samples (84 +/- 17), intermediate with samples that were B27 negative but B7 positive (118 +/- 13), and greatest with samples that were B27 positive (155 +/- 13). In addition to cross-reactivity with the B7 antigen (n = 38), the monoclonal anti-B27 cross-reacted with HLA-B37 positive samples (n = 3) and HLA-B39 positive samples (n = 3). Using a median channel fluorescence cutoff of 136, 39 of the 40 B27 positive samples gave positive results in the flow cytometric assay for a sensitivity of 97.6%. The specificity was 95.9% with 7 false positives of 169 B27 negative samples. The flow cytometric HLA-B27 assay is a convenient, useful screening test. For greatest specificity, samples positive by flow cytometry should be confirmed by conventional microlymphocytotoxicity or by use of other monoclonal antibodies directed against B27.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term stabilized blood samples as controls for flow cytometric HLA-B27 screening: a feasibility study.

BACKGROUND Long-term stabilized blood samples are potentially useful as positive or negative procedure controls for flow cytometric HLA-B27 screening, and could serve as test samples in an external quality assessment (EQA) scheme. We evaluated long-term stabilized whole blood specimens as prepared for the UK NEQAS for Leucocyte Immunophenotyping EQA scheme (Sheffield, UK). METHODS Peripheral ...

متن کامل

Validation of allele-specific polymerase chain reaction for DNA typing of HLA-B27.

To find a specific method for HLA-B27 typing for the diagnosis of rheumatic disorders, we extensively tested the single-step B27-specific polymerase chain reaction (PCR) described by Dominguez et al. (Immunogenetics 1992;36:277-82). This method, which relies on specific primer recognition of a sequence in the third exon (unique to the B27-allele), was used for screening of 270 characterized blo...

متن کامل

The flow cytometric labeling pattern in HLA-B27 detection may suggest cross reactivities

Background: The detection of HLA-B27 expression is one of the most powerful diagnostic tools in ankylosing spondylitis and other spondylarthropaties, hence the importance of a reliable and accurate detection method. Flow cytometry is often used as an alternative HLA-B27 typing technique, mainly because it is a rapid test. However, even though it is based on various monoclonal antibodies, their ...

متن کامل

HLA-B27 detection – comparison of genetic sequence-based method and flow cytometry assay

OBJECTIVES The presence of human leukocyte antigen B27 (HLA-B27) is strongly associated with ankylosing spondylitis. HLA-B27 testing is routinely applied in the diagnosis of this disease. The aim of the present study was to compare two methods of HLA-B27 detection - a genetic sequence-based method and a flow cytometry assay. MATERIAL AND METHODS Peripheral blood was obtained from 300 individu...

متن کامل

HLA-B27 phenotyping with flow cytometry: further improvement by multiple monoclonal antibodies.

To establish the optimal flow cytometric method for HLA-B27 phenotyping, we compared several strategies, using three monoclonal anti-B27 antibodies (from the HLA-ABC-m3, GS145.2, and FD705 clones). We used a triple-color direct immunofluorescence assay, including a T-lymphocyte-specific antibody as an internal control and an anti-HLA-Bw4 antibody. Blood samples from >400 subjects were tested. F...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cytometry

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 1995