Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses.

نویسندگان

  • P Bloomfield
  • D J Wheatley
  • R J Prescott
  • H C Miller
چکیده

BACKGROUND Patients undergoing heart-valve replacement may receive a mechanical prosthesis, necessitating lifelong anticoagulant treatment, or a porcine bioprosthesis, which involves no absolute need for anticoagulants. METHODS We carried out a randomized, prospective trial to compare the durability of the Bjork-Shiley mechanical prosthesis (spherical tilting-disk model) and the incidence of valve-related complications with those variables in the Hancock and the Carpentier-Edwards porcine prostheses. The mitral valve was replaced in 261 patients, the aortic valve in 211, and both in 61; the survivors have been followed up for a mean of 12 years. RESULTS We found a trend toward improved actuarial survival after 12 years with the Bjork-Shiley prosthesis, but this trend was not statistically significant (group with Bjork-Shiley valve vs. group with porcine valve [mean +/- SE], 51.5 +/- 3.2 vs. 44.4 +/- 3.2 percent; P = 0.08). There was no significant difference in the actuarial incidence of reoperation after 5 years, but after 12 years significantly more patients with a porcine prosthesis had undergone reoperation (8.5 +/- 2.0 vs. 37.1 +/- 4.1 percent, P less than 0.001). An analysis combining death and reoperation as end points for an actuarial assessment of survival with the original prosthesis intact confirmed that the patients with Bjork-Shiley Shiley prostheses had improved survival (48.6 +/- 3.2 vs. 30.0 +/- 3.0 percent after 12 years, P less than 0.001). Bleeding requiring hospitalization or blood transfusion was significantly more frequent in the patients with Bjork-Shiley prostheses (18.6 +/- 3.2 vs. 7.1 +/- 2.3 percent after 12 years, P less than 0.01). There was no significant difference after 12 years in the actuarial occurrence of embolism (Bjork-Shiley vs. porcine, 21.1 +/- 3.1 vs. 26.4 +/- 3.5 percent) or endocarditis (3.7 +/- 1.4 vs 4.6 +/- 1.6 percent). CONCLUSIONS Survival with an intact valve is better among patients with the Bjork-Shiley spherical tilting-disk prosthesis than among patients with porcine bioprostheses, but use of the Bjork-Shiley valve carries an attendant increased risk of bleeding associated with the need for anticoagulant treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CARDIOVASCULAR MEDICINE Twenty year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses

Objective: To compare survival and outcome in patients receiving a mechanical or bioprosthetic heart valve prosthesis. Design: Randomised prospective trial. Setting: Tertiary cardiac centre. Patients: Between 1975 and 1979, patients were randomised to receive either a Bjork-Shiley or a porcine prostheses. The mitral valve was replaced in 261 patients, the aortic in 211, and both valves in 61 pa...

متن کامل

Non-invasive assessment by Doppler ultrasound of 155 patients with bioprosthetic valves: a comparison of the Wessex porcine, low profile Ionescu-Shiley, and Hancock pericardial bioprostheses.

One hundred and fifty five patients with 167 bioprosthetic valves (68 Wessex porcine, 54 Hancock pericardial, and 45 low profile Ionescu-Shiley pericardial valves) were studied by Doppler ultrasound. Valve gradients were calculated from the mitral and aortic flow velocities by the modified Bernoulli equation. Mean mitral gradients were significantly smaller across the Ionescu-Shiley valves than...

متن کامل

Thirteen year-experience with mitral valve replacement.

At the Niigata University Hospital, various kinds of prosthetic valves such as the Starr-Edwards nonclothand cloth-covered, Bjork-Shiley tilting disc, and Carpentier-Edwards porcine valves, have been used from September, 1965 to March, 1979 for replacement of diseased valves on 176 patients. The patients with Starr-Edwards nonclothand cloth-covered ball valves showed survival rates of 90 and 84...

متن کامل

Haemolysis with Björk-Shiley and Starr-Edwards prosthetic heart valves: a comparative study.

Slater, S. D., Saflam, I. A., Bain, W. H., Turner, M. A., and Lawrie, T. D. V. (1974). Thorax, 29, 624-632. Haemolysis with Bjork-Shiley and Starr-Edwards prosthetic heart valves: a comparative study. A comparison was made of the haemolytic complications in 85 patients with two different types of Starr-Edwards cloth-covered ball and cage prosthesis with those in 44 patients with the Bjork-Shile...

متن کامل

Choice of prosthetic heart valve in today's practice.

In this update, current guidelines addressing prosthesis selection published by the American College of Cardiology/American Heart Association (ACC/AHA) and the European Society of Cardiology (ESC) are discussed, along with additional data that affect choices in valve prostheses. The case of a 50-year-old man undergoing aortic valve replacement is used to address anticipated operative mortality,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 89 7  شماره 

صفحات  -

تاریخ انتشار 1991