Organic Reference Materials for Hydrogen, Carbon, and Nitrogen Stable Isotope-Ratio Measurements: Caffeines, n-Alkanes, Fatty Acid Methyl Esters, Glycines, L-Valines, Polyethylenes, and Oils.

نویسندگان

  • Arndt Schimmelmann
  • Haiping Qi
  • Tyler B Coplen
  • Willi A Brand
  • Jon Fong
  • Wolfram Meier-Augenstein
  • Helen F Kemp
  • Blaza Toman
  • Annika Ackermann
  • Sergey Assonov
  • Anita T Aerts-Bijma
  • Ramona Brejcha
  • Yoshito Chikaraishi
  • Tamim Darwish
  • Martin Elsner
  • Matthias Gehre
  • Heike Geilmann
  • Manfred Gröning
  • Jean-François Hélie
  • Sara Herrero-Martín
  • Harro A J Meijer
  • Peter E Sauer
  • Alex L Sessions
  • Roland A Werner
چکیده

An international project developed, quality-tested, and determined isotope-δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope-δ scales. The RMs span a range of δ(2)H(VSMOW-SLAP) values from -210.8 to +397.0 mUr or ‰, for δ(13)C(VPDB-LSVEC) from -40.81 to +0.49 mUr and for δ(15)N(Air) from -5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C16 n-alkanes, n-C20-fatty acid methyl esters (FAMEs), glycines, and l-valines, together with polyethylene powder and string, one n-C17-FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a (2)H-enriched vacuum oil. A total of 11 laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic normalization against international primary measurement standards. The use of reference waters in silver tubes allowed direct normalization of δ(2)H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Because of exchangeable hydrogen, amino acid RMs currently are recommended only for carbon- and nitrogen-isotope measurements. Some amino acids contain (13)C and carbon-bound organic (2)H-enrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stable carbon isotope evidence for the microbial origin of C14-C18 n-alkanoic acids in soils

In order to delineate the origin of soil fatty acids, crop soil samples have been incubated for 21 days in vitro either with unlabelled or 13C-labelled glucose. Analyses of C14-C32 n-alkanoic acids from monocarboxylic acid fractions, as methyl esters, by gas chromatography-combustion-isotope ratio monitoring mass spectrometry (GC-C-IRMS) show that C14, C16 and C18 n-alkanoic acids are 13C-label...

متن کامل

Nicotine, acetanilide and urea multi-level 2H-, 13C- and 15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry.

Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the delta values of these reference materials should bracket the isotopic range of samples with unknown delta values. While the practice of analyzing two isotopica...

متن کامل

Stable carbon and hydrogen isotopic fractionation of individual n-alkanes accompanying biodegradation: evidence from a group of progressively biodegraded oils

Seven crude oils of known source and maturity, representing a natural sequence of increasing degree of biodegradation, were collected from reservoirs in the Liaohe Basin, NE China, in an effort to determine the magnitude and direction of isotopic shift of carbon and hydrogen in individual n-alkanes during microbial degradation. The results show that biodegradation has little effect on the carbo...

متن کامل

Single-step transesterification with simultaneous concentration and stable isotope analysis of fatty acid methyl esters by gas chromatography-combustion-isotope ratio mass spectrometry.

Gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) is increasingly applied to food and metabolic studies for stable isotope analysis (δ(13) C), with the quantification of analyte concentration often obtained via a second alternative method. We describe a rapid direct transesterification of triacylglycerides (TAGs) for fatty acid methyl ester (FAME) analysis by GC-C-IRMS d...

متن کامل

Fatty acid composition, antioxidant and antibacterial activities of Adonis wolgensis L. extract

Objectives: The objective of this study was to analyze the fatty acid content, antioxidant, and antibacterial activities of hydro-methanolic extract of Adonis wolgensis L. (A. wolgensis L.) growing wild in north of Iran. Materials and Methods: Oils of A. wolgensis L. was obtained by means of Soxhlet apparatus from leaves and stems. Methyl esters were derived from the oily mixtures by trans-este...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 88 8  شماره 

صفحات  -

تاریخ انتشار 2016