Agreement between an arterial blood gas analyser and a venous blood analyser in the measurement of potassium in patients in cardiac arrest.

نویسندگان

  • H L M Johnston
  • R Murphy
چکیده

BACKGROUND AND OBJECTIVE Rapid measurement of potassium is crucial in the resuscitation of patients in cardiac arrest. This is often done on an arterial blood gas sample taken during resuscitation and analysed in an emergency department based blood gas analyser. No-one has assessed how accurate or reliable this is when compared with the traditional method of sending a venous sample to the laboratory for standard analysis. This study looked at the agreement between potassium measurements in arterial blood gas samples and venous blood samples in patients in cardiac arrest. METHOD Arterial and venous blood samples were taken at the same time and analysed in the usual way from 50 patients in cardiac arrest. It was found that the mean difference between each pair of arterial and venous potassium measurements was low at 0.106 mmol/l. However, the standard deviation of these differences and subsequently the 95% limits of agreement were wide (-1.182 mmol/l to 1.394 mmol/l)-that is, 95% of differences will lie between these limits. It is felt that these limits are too wide for safe use in clinical practice. CONCLUSION Based on these results, it is advised that arterial blood gas analysers should be used with caution to measure potassium in patients in cardiac arrest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective study of blood glucose detection using arterial blood gas analysis and peripheral glucometry after cardiac surgery with cardiopulmonary bypass: accuracy and influences

The objectives of this study were to evaluate the accuracy of blood glucose measurements and to analyze the clinicopathological and experimental factors affecting the accuracy of blood glucose measurement devices. The study enrolled 172 patients who underwent cardiac surgery with cardiopulmonary bypass. Arterial, peripheral, and venous blood samples were collected simultaneously every hour to 1...

متن کامل

Comparison of the point-of-care blood gas analyzer versus the laboratory auto-analyzer for the measurement of electrolytes

BACKGROUND Electrolyte values are measured both by arterial blood gas (ABG) analyzers and central laboratory auto-analyzers (AA), but a significant time gap exists between the availability of both these results, with the ABG giving faster results than the AA. The authors hypothesized that there is no difference between the results obtained after measurement of electrolytes by the blood gas and ...

متن کامل

Agreement of arterial sodium and arterial potassium levels with venous sodium and venous potassium in patients admitted to intensive care unit.

INTRODUCTION Electrolyte abnormalities are one of the common causes of morbidity and mortality in critically ill patients. The turnaround time for electrolyte reporting should be as low as possible. Electrolytes are measured conventionally in serum obtained from venous blood by electrolyte analyser which takes 20 to 30 min. Point of care analysers are now available where in electrolytes can be ...

متن کامل

اثر تزریق مداوم (اینفیوژن) دوزپائین کتامین برتغییرات همودینامیک در جراحی پیوند عروق کرونر

Background & objectives: Cardiopulmonary bypass often causes a stress hormonal response with subsequent changes in hemodynamic and organ perfusion. Human studies involving cardiopulmonary bypass have shown that very low doses of ketamine can attenuate inflammatory and stress markers, without adverse effects. The aim of this study was to investigate whether low dose infusion of ketamine have hem...

متن کامل

Hemodynamic and Arterial Blood Gas Parameters during Cemented Hip Hemiarthroplasty in Elderly Patients

Background:  Patients undergoing cemented hip hemiarthroplasty may develop bone cement implantation syndrome (BCIS) which is a leading cause of intraoperative complications. The purpose of this study was to evaluate cardiovascular changes during cemented hip hemiarthroplasty in elderly patients.   Methods:  Cemented hip hemiarthroplasty was performed on 72 patients with femoral neck fracture. A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Emergency medicine journal : EMJ

دوره 22 4  شماره 

صفحات  -

تاریخ انتشار 2005