Use of a bipolar sealer in total hip arthroplasty: medical resource use and costs using a hospital administrative database.

نویسندگان

  • Stacey J Ackerman
  • Crisanta I Tapia
  • Rebecca Baik
  • Robert Pivec
  • Michael A Mont
چکیده

Perioperative blood loss during total hip arthroplasty (THA) increases patient morbidity, length of stay (LOS), medical resource use (MRU), and costs. Minimizing blood loss may reduce postoperative anemia, the need for blood transfusions, and the increased risk of infections and longer hospital stays associated with blood transfusions. Pharmacologic agents and bipolar sealer devices can minimize perioperative bleeding. A retrospective, comparative cohort study in the US hospital setting was conducted to assess MRU and associated costs and the incidence of transfusion and complications among patients undergoing THA with or without the use of a bipolar sealer. Using a nationwide all-payer hospital administrative database, THA procedures from January 1, 2008, to March 31, 2011, were identified using International Classification of Diseases, Ninth Revision, Clinical Modification procedure code 81.51. The bipolar sealer cohort (n=2683) and matched control cohort (n=2683) had a mean age of 65 years from 38 hospitals. The 2 groups had similar incidences of pre-operative anemia and medical comorbidities. Patients in the bipolar sealer group required significantly fewer blood transfusions (21.3% vs 23.8%; P=.0286) and had significantly lower incidence of hematomas (0.2% vs 0.9%; P=.0015) and significantly shorter LOS (2.90 vs 3.31 days; P<.0001) overall. The bipolar sealer group had higher supply costs, which were offset by reduced hospital inpatient room and board and operating room costs; there was no significant difference in total hospital costs between the 2 groups ($18,937 vs $18,734; P=.56). A bipolar sealer decreases postoperative blood transfusions and LOS during primary THA without increasing total hospital costs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bipolar sealer not superior to standard electrocautery in primary total hip arthroplasty: a meta-analysis

INTRODUCTION To assess whether bipolar sealer has advantages over standard electrocautery in primary total hip arthroplasty (THA). METHODS All studies published through November 2013 were systematically searched in PubMed, Embase, ScienceDirect, The Cochrane Library, and other databases. Relevant journals or conference proceedings were searched manually. Only randomized controlled trials were...

متن کامل

The Use of Antibiotic Impregnated Cement Spacers in the Treatment of Infected Total Joint Replacement: Challenges and Achievements

Two stage total hip arthroplasty revision surgery includes foreign material debridment, insertion of antibiotic impregnatedcement spacer, and finally, reimplantation of the prosthesis. This review has aimed to evaluate the efficacy of antibioticimpregnated cement spacers in infection control and eradication in arthroplasties.A total of 85 articles on total hip arthroplasty wer...

متن کامل

In-Hospital Outcomes after Hemiarthroplasty versus Total Hip Arthroplasty for Isolated Femoral Neck Fractures

  Background:    Previous studies suggest total hip arthroplasty may have some benefits compared to hemi-arthroplasty for displaced intracapsular femoral neck fractures in patients more than 60 years of age. The primary research question of our study was whether in-hospital adverse events, post-operative length of stay (LOS) and mortality in patients 60 year of age or older differed between tot...

متن کامل

Use of a saline-coupled bipolar sealer open liver resection for hepatic malignancy: Medical resource use and costs

AIM To evaluate outcomes associated with use of a saline coupled bipolar sealer during open partial liver resection. METHODS This retrospective analysis utilized the United States Premier™ insurance claims database (2010-2014). Patients were selected with codes for liver malignancy and partial hepatectomy or lobectomy. Cases were defined by use the saline-coupled bipolar sealer; controls had ...

متن کامل

The Efficacy of Bipolar Sealer on Blood Loss in Primary Total Hip Arthroplasty

The blood loss during total hip arthroplasty is difficult to manage and there is no consensus about the effect of bipolar sealer used during operation. Thus, a systematic review of randomized controlled trials (RCTs) was performed to evaluate the efficacy and safety of blood loss using bipolar sealer after total hip arthroplasty (THA).Relevant literature of comparisons of bipolar sealer after T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 37 5  شماره 

صفحات  -

تاریخ انتشار 2014