Pure-tone audiometry outside a sound booth using earphone attentuation, integrated noise monitoring, and automation.
نویسندگان
چکیده
OBJECTIVE Accessibility of audiometry is hindered by the cost of sound booths and shortage of hearing health personnel. This study investigated the validity of an automated mobile diagnostic audiometer with increased attenuation and real-time noise monitoring for clinical testing outside a sound booth. DESIGN Attenuation characteristics and reference ambient noise levels for the computer-based audiometer (KUDUwave) was evaluated alongside the validity of environmental noise monitoring. Clinical validity was determined by comparing air- and bone-conduction thresholds obtained inside and outside the sound booth (23 subjects). STUDY SAMPLE Twenty-three normal-hearing subjects (age range, 20-75 years; average age 35.5) and a sub group of 11 subjects to establish test-retest reliability. RESULTS Improved passive attenuation and valid environmental noise monitoring was demonstrated. Clinically, air-conduction thresholds inside and outside the sound booth, corresponded within 5 dB or less > 90% of instances (mean absolute difference 3.3 ± 3.2 SD). Bone conduction thresholds corresponded within 5 dB or less in 80% of comparisons between test environments, with a mean absolute difference of 4.6 dB (3.7 SD). Threshold differences were not statistically significant. Mean absolute test-retest differences outside the sound booth was similar to those in the booth. CONCLUSION Diagnostic pure-tone audiometry outside a sound booth, using automated testing, improved passive attenuation, and real-time environmental noise monitoring demonstrated reliable hearing assessments.
منابع مشابه
Validity of diagnostic pure-tone audiometry without a sound-treated environment in older adults.
OBJECTIVE To investigate the validity of diagnostic pure-tone audiometry in a natural environment using a computer-operated audiometer with insert earphones covered by circumaural earcups incorporating real-time monitoring of environmental noise. DESIGN A within-subject repeated measures design was employed to compare air (250 to 8000 Hz) and bone (250 to 4000 Hz) conduction pure-tone thresho...
متن کاملHearing Tests Based on Biologically Calibrated Mobile Devices: Comparison With Pure-Tone Audiometry
BACKGROUND Hearing screening tests based on pure-tone audiometry may be conducted on mobile devices, provided that the devices are specially calibrated for the purpose. Calibration consists of determining the reference sound level and can be performed in relation to the hearing threshold of normal-hearing persons. In the case of devices provided by the manufacturer, together with bundled headph...
متن کاملValidation of a Self-Administered Audiometry Application: An Equivalence Study.
OBJECTIVES/HYPOTHESIS To compare hearing measurements made at home using self-administered audiometric software against audiological tests performed on the same subjects in a clinical setting STUDY DESIGN Prospective, crossover equivalence study METHODS In experiment 1, adults with varying degrees of hearing loss (N = 19) performed air-conduction audiometry, frequency discrimination, and sp...
متن کاملA noise-attenuating enclosure for audiometer earphones.
Noise-excluding earphones may be subdivided into circumaural earphones and noise-attenuating earphone enclosures. Two versions of 'Otocups', an example of the latter subdivision, were evaluated in a series of experiments and in comparison with a conventional type of earphone (Telephonics TDH-39 receiver in a MX-4I /AR cushion). The experiments involved a comparison of auditory threshold, artifi...
متن کاملEffects of background noise on earphone thresholds.
Real-ear attenuation at threshold (REAT) and monaural pure-tone thresholds were determined for normally hearing adults using a supra-aural, Audiocup, and insert earphone. The thresholds were obtained in quiet and in background noises approximating the maximum permissible ambient noise levels (MPANLs) allowed in an audiometric test room specified by ANSI S3.1-1991 and OSHA (1983). The supra-aura...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of audiology
دوره 54 11 شماره
صفحات -
تاریخ انتشار 2015