Finite element analysis of lumbosacral reconstruction after partial sacrectomy
نویسندگان
چکیده
BACKGROUND The biomechanical property of MGT for patients who underwent partial sacrectomy is not well documented, so this study aimed to investigate biomechanical property of lumbosacral reconstruction after partial sacrectomy. MATERIAL AND METHODS Three 3-dimensional finite element models of lumbosacral region were established: 1) an intact model (INT), 2) a defective model in which partial sacrectomy was performed cephalad to S1 foramina (DEF), and 3) a reconstructed model (REC). RESULTS Displacements of anchor point on L3 vertebrae in INT, DEF, and REC model were 6.63 mm, 10.62 mm, 4.29 mm (titanium), and 3.86mm (stainless steel), respectively. Stress distribution of the instrument in REC model showed excessive concentration on the caudal spinal rod, which may cause rod failure between spine and ilia. Maximum von Mise stress of the stainless steel instrument was higher than titanium instruments, and values of stress of the anchor point around the sacroiliac joint in the REC model were 26.4 MPa with titanium instruments and 23.9MPa with stainless steel instruments. CONCLUSIONS Lumbosacral reconstruction can significantly increase stiffness of the spinopelvis of patients who underwent partial sacrectomy. However, the rod between L5 and ilia is the weakest region of all instruments. Stainless steel instruments have higher risk of rod failure and are less suitable for lumboiliac arthrodesis than titanium instruments.
منابع مشابه
Pelvic Reconstruction Surgery Using a Dual-Rod Technique with Diverse U-Shaped Rods After Posterior En Bloc Partial Sacrectomy for a Sacral Tumor: 2 Case Reports and a Literature Review.
BACKGROUND Spinopelvic reconstruction after sacrectomy for a sacropelvic tumor can result in various complications and requires a highly complicated surgical technique. We report 2 cases of pelvic reconstruction surgery using diverse U-shaped rods (USRs) after partial sacrectomy. CASE DESCRIPTION A partial sacrectomy was performed for 2 different cases: one case was a metastatic sacral tumor ...
متن کاملStress Analysis of the Human Ligamentous Lumber Spine-From Computer-Assisted Tomography to Finite Element Analysis
Detailed investigation on biomechanics of a complex structure such as the human lumbar spine requires the use of advanced computer-based technique for both the geometrical reconstruction and the stress analysis. In the present study, the computer-assisted tomography (CAT) and finite element method (FEM) are merged to perform detailed three dimensional nonlinear analysis of the human ligamentous...
متن کاملFinite Element Instability Analysis of the Steel Joist of Continuous Composite Beams with Flexible Shear Connectors
Composite steel/concrete beams may buckle in hogging bending regions. As the top flange of I-beam in that arrangement is restricted from any translational deformation and twist, the web will distort during buckling presenting a phenomenon often described as restricted distortional buckling. There are limited studies available in the literature of restricted distortional buckling of composite st...
متن کاملManagement of Sacral Tumors Requiring Spino-Pelvic Reconstruction with Different Histopathologic Diagnosis: Evaluation with Four Cases
In this retrospective study, surgical results of four patients with sacral tumors having disparate pathologic diagnoses, who were treated with partial or total sacrectomy and lumbopelvic stabilization were abstracted. Two patients were treated with partial sacral resection and two patients were treated with total sacrectomy and spinopelvic fixation. Fixation methods included spinopelvic fixatio...
متن کاملThe Strain at Bone-Implant Interface Determines the Effect of Spinopelvic Reconstruction following Total Sacrectomy: A Strain Gauge Analysis in Various Spinopelvic Constructs
PURPOSE There is still some controversy regarding the optimal biomechanical concept for spinopelvic stabilization following total sacrectomy for malignancy. Strains at specific anatomical sites at pelvis/sacrum and implants interfaces have been poorly investigated. Herein, we compared and analyzed the strains applied at key points at the bone-implant interface in four different spinopelvic cons...
متن کامل