Intermittent loss of capture in a His bundle pacemaker: What is the cause?

نویسندگان

  • Santosh K. Padala
  • Kenneth A. Ellenbogen
  • Jayanthi N. Koneru
چکیده

Case report A 34-year-old man with a history of congenital complete heart block who underwent dual-chamber pacemaker implant at age 6 and multiple generator changes was referred for device replacement and lead extraction owing to malfunctioning atrial and ventricular leads. He underwent lead extraction of a dual-chamber pacing system with subsequent reimplantation of a Medtronic Viva CRT pacemaker (CRTP) generator and bipolar active fixation leads in the right atrium, right ventricle, and His bundle (LV port). The sensing, pacing threshold, and impedance measurements for all 3 leads were stable. On postoperative day 1, to promote His bundle–only pacing without RV pacing, the device was reprogrammed to have a subthreshold RV output of 0.50 V at 0.03 ms. Device parameters are shown in Table 1. On postoperative day 2, rhythm strips were obtained (Figure 1) on telemetry. What is the cause of intermittent loss of capture, and what programming changes would be most appropriate to resolve the issue?

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

His bundle capture proximal to the site of bundle branch block: A novel pitfall of the para-Hisian pacing maneuver

Paced QRS morphology should be assessed to differentiate between complete loss of His bundle capture and loss of distal His bundle capture alone. This might be enough in patients with proximal right bundle branch block; however, in patients with proximal left bundle branch block, QRS morphology might be similar with loss of His bundle capture and with proximal His bundle capture. Introduction T...

متن کامل

THE ROLE OF PACEMAKER CLINIC IN THE FOLLOW-UP OF PATIENTS WITH PERMANENT PACEMAKERS

The Pacemaker Clinic at Shahid Rajai Cardiovascular Research Center first started operating in August 1992. In its first year of operation, 294 permanent pacemaker patients were studied, allowing an appraisal to be carried out of the clinic's effectiveness in diagnosing and treating early complications. In the final analysis, pacemaker complications were observed in 68 (23%) patients, of wh...

متن کامل

Depression of escape pacemakers associated with rapid supraventricular rate in patients with atrioventricular block.

Intermittent failure of escape pacemakers to maintain an effective rate when the supraventricular rate was rapid was observed in three patients with complete, or high degree atrioventricular block. In two of these patients asystole or slowing of escape pacemaker rate to less than 20 per minute was reproduced by atrial pacing at rates from 125 to 150 per minute. We localized the site of the bloc...

متن کامل

The Improvement of the Atrial Flutter Rhythm upon the Removal of the Infected Permanent Pacemaker Lead

Pacemaker infection has multiple risk factors. Its presentation is most often similar to infected endocarditis and the diagnosis is made through studying blood cultures. Transesophageal echocardiography can confirm the diagnosis. The most common microorganisms are staphylococcus speciesis. As a matter of fact, complete pacemaker removal appears to be the only definite treatment. We presented a ...

متن کامل

Disorders of cellular electrophysiology produced by ischemia of the canine His bundle.

In the first 4 hours after occlusion of the anterior septal coronary artery, 18 dogs developed bundle branch block, heart block, or both. The hearts were then excised, and preparations were dissected to expose the His bundle and the bundle branches, which were superfused with modified Tyrode's solution at 37 degrees C. In the His bundle and the most proximal bundle branches, resting potentials ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2017