Detailed analysis of latencies in image-based dynamic MLC tracking.

نویسندگان

  • Per Rugaard Poulsen
  • Byungchul Cho
  • Amit Sawant
  • Dan Ruan
  • Paul J Keall
چکیده

PURPOSE Previous measurements of the accuracy of image-based real-time dynamic multileaf collimator (DMLC) tracking show that the major contributor to errors is latency, i.e., the delay between target motion and MLC response. Therefore the purpose of this work was to develop a method for detailed analysis of latency contributions during image-based DMLC tracking. METHODS A prototype DMLC tracking system integrated with a linear accelerator was used for tracking a phantom with an embedded fiducial marker during treatment delivery. The phantom performed a sinusoidal motion. Real-time target localization was based on x-ray images acquired either with a portal imager or a kV imager mounted orthogonal to the treatment beam. Each image was stored in a file on the imaging workstation. A marker segmentation program opened the image file, determined the marker position in the image, and transferred it to the DMLC tracking program. This program estimated the three-dimensional target position by a single-imager method and adjusted the MLC aperture to the target position. Imaging intervals deltaT(image) from 150 to 1000 ms were investigated for both kV and MV imaging. After the experiments, the recorded images were synchronized with MLC log files generated by the MLC controller and tracking log files generated by the tracking program. This synchronization allowed temporal analysis of the information flow for each individual image from acquisition to completed MLC adjustment. The synchronization also allowed investigation of the MLC adjustment dynamics on a considerably finer time scale than the 50 ms time resolution of the MLC log files. RESULTS For deltaT(image) = 150 ms, the total time from image acquisition to completed MLC adjustment was 380 +/- 9 ms for MV and 420 +/- 12 ms for kV images. The main part of this time was from image acquisition to completed image file writing (272 ms for MV and 309 ms for kV). Image file opening (38 ms), marker segmentation (4 ms), MLC position calculation (16 ms), and MLC adjustment (52 ms) were considerably faster. For deltaT(image) = 1000 ms, the total time from image acquisition to completed MLC adjustment increased to 1030 +/- 62 ms (MV) and 1330 +/- 52 ms (kV) mainly because of delayed image file writing. The MLC adjustment duration was constant 52 ms (+/- 3 ms) for MLC adjustments below 1.1 mm and increased linearly for larger MLC adjustments. CONCLUSIONS A method for detailed time analysis of each individual real-time position signal for DMLC tracking has been developed and applied to image-based tracking. The method allows identification of the major contributors to latency and therefore a focus for reducing this latency. The method could be an important tool for the reconstruction of the delivered target dose during DMLC tracking as it provides synchronization between target motion and MLC motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback

Background: Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy. Objective: This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic multi-leaf collimators. Material and Methods: All slices which contained tumor were contoured in the 4D-CT images for...

متن کامل

First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking.

PURPOSE For intrafraction motion management, a real-time tracking system was developed by combining fiducial marker-based tracking via simultaneous kilovoltage (kV) and megavoltage (MV) imaging and a dynamic multileaf collimator (DMLC) beam-tracking system. METHODS AND MATERIALS The integrated tracking system employed a Varian Trilogy system equipped with kV/MV imaging systems and a Millenniu...

متن کامل

Delivery of four‐dimensional radiotherapy with TrackBeam for moving target using a dual‐layer MLC: dynamic phantoms study

Respiratory motion has been considered a clinical challenge for lung tumor treatments due to target motion. In this study, we aimed to perform an experimental evaluation based on dynamic phantoms using MLC-based beam tracking. TrackBeam, a prototype real-time beam tracking system, has been assembled and evaluated in our clinic. TrackBeam includes an orthogonal dual-layer micro multileaf collima...

متن کامل

Computation Optical Flow Using Pipeline Architecture

Accurate estimation of motion from time-varying imagery has been a popular problem in vision studies, This information can be used in segmentation, 3D motion and shape recovery, target tracking, and other problems in scene analysis and interpretation. We have presented a dynamic image model for estimating image motion from image sequences, and have shown how the solution can be obtained from a ...

متن کامل

Analysis and Synthesis of Facial Expressions by Feature-Points Tracking and Deformable Model

Face expression recognition is useful for designing new interactive devices offering the possibility of new ways for human to interact with computer systems. In this paper we develop a facial expressions analysis and synthesis system. The analysis part of the system is based on the facial features extracted from facial feature points (FFP) in frontal image sequences. Selected facial feature poi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 37 9  شماره 

صفحات  -

تاریخ انتشار 2010