Planck pre-launch status: Expected LFI polarisation capability

نویسندگان

  • J. P. Leahy
  • M. Bersanelli
  • S. M. Leach
  • A. Moss
  • E. Keihänen
  • R. Keskitalo
  • H. Kurki-Suonio
  • T. Poutanen
  • M. Sandri
  • D. Scott
  • J. Tauber
  • L. Valenziano
  • F. Villa
  • A. Wilkinson
  • A. Zonca
  • C. Baccigalupi
  • J. Borrill
  • R. C. Butler
  • F. Cuttaia
  • R. J. Davis
  • M. Frailis
  • N. Mandolesi
  • M. Maris
  • P. Meinhold
  • L. Mendes
  • A. Mennella
چکیده

We present a system-level description of the Low Frequency Instrument (LFI) considered as a differencing polarimeter, and evaluate its expected performance. The LFI is one of the two instruments on board the ESA Planck mission to study the cosmic microwave background. It consists of a set of 22 radiometers sensitive to linear polarisation, arranged in orthogonally-oriented pairs connected to 11 feed horns operating at 30, 44 and 70 GHz. In our analysis, the generic Jones and Mueller-matrix formulations for polarimetry are adapted to the special case of the LFI. Laboratory measurements of flight components are combined with optical simulations of the telescope to investigate the values and uncertainties in the system parameters affecting polarisation response. Methods of correcting residual systematic errors are also briefly discussed. The LFI has beam-integrated polarisation efficiency >99% for all detectors, with uncertainties below 0.1%. Indirect assessment of polarisation position angles suggests that uncertainties are generally less than 0. ◦5, and this will be checked in flight using observations of the Crab nebula. Leakage of total intensity into the polarisation signal is generally well below the thermal noise level except for bright Galactic emission, where the dominant effect is likely to be spectral-dependent terms due to bandpass mismatch between the two detectors behind each feed, contributing typically 1–3% leakage of foreground total intensity. Comparable leakage from compact features occurs due to beam mismatch, but this averages to <5 × 10−4 for large-scale emission. An inevitable feature of the LFI design is that the two components of the linear polarisation are recovered from elliptical beams which differ substantially in orientation. This distorts the recovered polarisation and its angular power spectrum, and several methods are being developed to correct the effect, both in the power spectrum and in the sky maps. The LFI will return a high-quality measurement of the CMB polarisation, limited mainly by thermal noise. To meet our aspiration of measuring polarisation at the 1% level, further analysis of flight and ground data is required. We are still researching the most effective techniques for correcting subtle artefacts in polarisation; in particular the correction of bandpass mismatch effects is a formidable challenge, as it requires multi-band analysis to estimate the spectral indices that control the leakage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Planck pre-launch status: Calibration of the Low Frequency Instrument flight model radiometers

The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called radiometer chain assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cry...

متن کامل

Planck pre-launch status: HFI beam expectations from the optical optimisation of the focal plane

Planck is a European Space Agency (ESA) satellite, launched in May 2009, which will map the cosmic microwave background anisotropies in intensity and polarisation with unprecedented detail and sensitivity. It will also provide full-sky maps of astrophysical foregrounds. An accurate knowledge of the telescope beam patterns is an essential element for a correct analysis of the acquired astrophysi...

متن کامل

ar X iv : a st ro - p h / 99 04 13 5 v 1 1 2 A pr 1 99 9 The Planck Low Frequency Instrument

– The Low Frequency Instrument (LFI) of the " Planck Surveyor " ESA mission will perform high-resolution imaging of the Cosmic Microwave Background anisotropies at four frequencies in the 30–100 GHz range. We review the LFI main scientific objectives, the current status of the instrument design and the ongoing effort to develop software simulations of the LFI observations. In particular we disc...

متن کامل

Zodiacal Light Emission in the Planck mission

Context. The Planck satellite, scheduled for launch in 2007, will produce a set of all sky maps in nine frequency bands spanning from 30 GHz to 857 GHz, with an unprecedented sensitivity and resolution. Planets, minor bodies and diffuse interplanetary dust will contribute to the (sub)mm sky emission observed by Planck, representing a source of foreground contamination to be removed before extra...

متن کامل

Extracting cosmic microwave background polarisation from satellite astrophysical maps

We present the application of the Fast Independent Component Analysis (FastICA) technique for blind component separation to polarised astrophysical emission. We study how the Cosmic Microwave Background (CMB) polarised signal, consisting of E and B modes, can be extracted from maps affected by substantial contamination from diffuse Galactic foregrounds and instrumental noise. We perform the ana...