Specimen size and porosity can introduce error into microCT-based tissue mineral density measurements.

نویسندگان

  • Roberto J Fajardo
  • Esther Cory
  • Nipun D Patel
  • Ara Nazarian
  • Andres Laib
  • Rajaram K Manoharan
  • James E Schmitz
  • Jeremy M DeSilva
  • Laura M MacLatchy
  • Brian D Snyder
  • Mary L Bouxsein
چکیده

The accurate measurement of tissue mineral density, rho(m), in specimens of unequal size or quantities of bone mineral using polychromatic microCT systems is important, since studies often compare samples with a range of sizes and bone densities. We assessed the influence of object size on microCT measurements of rho(m) using (1) hydroxyapatite rods (HA), (2) precision-manufactured aluminum foams (AL) simulating trabecular bone structure, and (3) bovine cortical bone cubes (BCt). Two beam-hardening correction (BHC) algorithms, determined using a 200 and 1200 mg/cm(3) HA wedge phantom, were used to calculate rho(m) of the HA and BCt. The 200 mg/cm(3) and an aluminum BHC algorithm were used to calculate the linear attenuation coefficients of the AL foams. Equivalent rho(m) measurements of 500, 1000, and 1500 mg HA/cm(3) rods decreased (r(2)>0.96, p<0.05 for all) as HA rod diameter increased in the 200 mg/cm(3) BHC data. Errors averaged 8.2% across these samples and reached as high as 29.5%. Regression analyses suggested no size effects in the 1200 mg/cm(3) BHC data but differences between successive sizes still reached as high as 13%. The linear attenuation coefficients of the AL foams increased up to approximately 6% with increasing volume fractions (r(2)>0.81, p<0.05 for all) but the strength of the size-related error was also BHC dependent. Equivalent rho(m) values were inversely correlated with BCt cube size (r(2)>0.92, p<0.05). Use of the 1200 mg/cm(3) BHC ameliorated the size-related artifact compared to the 200 mg/cm(3) BHC but errors with this BHC were still significant and ranged between 5% and 12%. These results demonstrate that object size, structure, and BHC algorithm can influence microCT measurements of rho(m). Measurements of rho(m) of specimens of unequal size or quantities of bone mineral must be interpreted with caution unless appropriate steps are taken to minimize these potential artifacts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative micro-computed tomography: a non-invasive method to assess equivalent bone mineral density.

One of the many applications of micro computed tomography (microCT) is to accurately visualize and quantify cancellous bone microstructure. However, microCT based assessment of bone mineral density has yet to be thoroughly investigated. Specifically, the effects of varying imaging parameters, such as tube voltage (kVp), current (microA), integration time (ms), object to X-ray source distance (m...

متن کامل

Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.

Bone mineral density (BMD) measurements are critical in many research studies investigating skeletal integrity. For pre-clinical research, micro-computed tomography (microCT) has become an essential tool in these studies. However, the ability to measure the BMD directly from microCT images can be biased by artifacts, such as beam hardening, in the image. This three-part study was designed to un...

متن کامل

Characterization of Heterotopic Ossification Using Radiographic Imaging: Evidence for a Paradigm Shift

Heterotopic ossification (HO) is the growth of extra-skeletal bone which occurs following trauma, burns, and in patients with genetic bone morphogenetic protein (BMP) receptor mutations. The clinical and laboratory evaluation of HO is dependent on radiographic imaging to identify and characterize these lesions. Here we show that despite its inadequacies, plain film radiography and single modali...

متن کامل

Effect of integration time on the morphometric, densitometric and mechanical properties of the mouse tibia.

Micro-Computed Tomography (microCT) images are used to measure morphometric and densitometric properties of bone, and to develop finite element (FE) models to estimate mechanical properties. However, there are concerns about the invasiveness of microCT imaging due to the X-rays ionising radiation induced by the repeated scans on the same animal. Therefore, the best compromise between radiation ...

متن کامل

Guidelines for assessment of bone microstructure in rodents using micro-computed tomography.

Use of high-resolution micro-computed tomography (microCT) imaging to assess trabecular and cortical bone morphology has grown immensely. There are several commercially available microCT systems, each with different approaches to image acquisition, evaluation, and reporting of outcomes. This lack of consistency makes it difficult to interpret reported results and to compare findings across diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bone

دوره 44 1  شماره 

صفحات  -

تاریخ انتشار 2009