The paper electrophoretic separation of phosphatides.
نویسندگان
چکیده
A number of chromatographic methods have been previously reported for the separation of phosphatides. Column chromatography has been used successfully by Thannhauser and Setz (l), Klenk (a), and Hanahan et al. (3). Paper chromatographic techniques for phosphatide analysis have been reported by Bevan et al. (4), Hecht and Mink (5), Hack (6)) and Lea et al. (7). Garvin (8) has reported a separation of phosphatides by filter paper electrophoresis. In the present paper, a method for the separation of phosphatides by electrophoresis on a paper strip is described. This method is a result of the successful use of non-aqueous solvents and solvent systems containing low concentrations of water. The use of such solvents was first described by Paul and Durrum in 1952 (9). Experimental-Lecithin was prepared by a combination of the methods of Pangborn (lo), Taurog et al. (II), and Lea et al. (7). Three samples of synthetic lecithin analogues were kindly supplied by Dr. E. Baer and Dr. J. D. MacLennan. These included dimyristoyllecithin, dioleoyllecithin, and glycol stearyl lecithin. Cephalin was prepared and fractionated by the method of Folch (12-14)) which provides for the separation of three phosphatides: phosphatidylethanolamine, phosphatidylserine, and diphosphoinositide. Analytical-With the exception of the diphosphoinositide, the purity of the sample was based on the ratio of nitrogen to phosphorus. Phosphorus was determined by the method of King (15) and nitrogen by the microDumas method. The results are shown in Table I. Apparatus-The apparatus used was an electrophoresis unit designed by Dr. Samuel Raymond of the E. C. Apparatus Company, and consists of three separate buffer chambers, each provided with baffle plates. Between the opposing buffer chambers there is situated a 12 inch long watercooled plate. The power supply provided a potential of 1000 volts and a current of 200 ma. Method-An electrophoretic determination was conducted in the following manner: the electrolyte system was added to the buffer compartments of the apparatus, and the Whatman No. 3MR!I paper strips were placed on a Teflon pad with the ends of the paper strips kept out of the solvent system.
منابع مشابه
Separation of Glycosyl Diglycerides from Phosphatides Using Silicic Acid Column Chromatography.
A procedure has been developed for the separation of the glycosyl diglycerides from the phosphatides of Gram-positive bacteria on columns of silicic acid. The method utilizes mixtures of acetone in chloroform for elution of the glycosyl diglycerides, followed by increasing amounts of methanol in chloroform for elution of the phosphatides. The course of the fractionation was followed by means of...
متن کاملImprovement of Capillary Electrophoretic Enantioseparation of Fluoxetine by a Cationic Additive
One of the problems encountered in CE separations of basic compounds is the adsorption of analytes onto the negatively charged capillary wall which could lead to poor repeatability of migration time and peak area. Additionally, separation of enantiomers of chiral of basic drugs is commonly carried out in low pH buffer which contributes to strong ionic interaction of the cationic drug ions with ...
متن کاملImprovement of Capillary Electrophoretic Enantioseparation of Fluoxetine by a Cationic Additive
One of the problems encountered in CE separations of basic compounds is the adsorption of analytes onto the negatively charged capillary wall which could lead to poor repeatability of migration time and peak area. Additionally, separation of enantiomers of chiral of basic drugs is commonly carried out in low pH buffer which contributes to strong ionic interaction of the cationic drug ions with ...
متن کاملStudies on the Phosphatide Content of Human Serum* by Menard
Recent observations appear to indicate that there is an association between human atherosclerosis and gross changes in serum phosphatides (1, 2). Since this lipide fraction is heterogeneous, it would be desirable and of interest to distinguish any differential changes in the individual phosphatide components. The examination of the literature dealing with the qualitative and quantitative aspect...
متن کاملImprovement of Electrophoretic Enantioseparation of Amlodipine by Polybrene
In chiral and non-chiral electrophoretic resolution of basic drugs, adsorption of analytes to negatively charged capillary wall could lead to poor repeatability of migration time and peak area. In addition, chiral resolutions of basic drugs are commonly performed in low pH buffers. Therefore, longer analysis time due to suppression of electroosmotic flow (EOF) is another dilemma. In this wor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of biological chemistry
دوره 230 2 شماره
صفحات -
تاریخ انتشار 1958