Interlocking Nailing Versus Interlocking Plating in Intra-articular Calcaneal Fractures: A Biomechanical Study.

نویسندگان

  • Sophia Reinhardt
  • Heiner Martin
  • Benjamin Ulmar
  • Stefan Döbele
  • Hans Zwipp
  • Stefan Rammelt
  • Martinus Richter
  • Martin Pompach
  • Thomas Mittlmeier
چکیده

BACKGROUND Open reduction and internal fixation with a plate is deemed to represent the gold standard of surgical treatment for displaced intra-articular calcaneal fractures. Standard plate fixation is usually placed through an extended lateral approach with high risk for wound complications. Minimally invasive techniques might avoid wound complications but provide limited construct stability. Therefore, 2 different types of locking nails were developed to allow for minimally invasive technique with sufficient stability. The aim of this study was to quantify primary stability of minimally invasive calcaneal interlocking nail systems in comparison to a variable-angle interlocking plate. MATERIAL AND METHODS After quantitative CT analysis, a standardized Sanders type IIB fracture model was created in 21 fresh-frozen cadavers. For osteosynthesis, 2 different interlocking nail systems (C-Nail; Medin, Nov. Město n. Moravě, Czech Republic; Calcanail; FH Orthopedics SAS; Heimsbrunn, France) as well as a polyaxial interlocking plate (Rimbus; Intercus GmbH; Rudolstadt, Germany) were used. Biomechanical testing consisted of a dynamic load sequence (preload 20 N, 1000 N up to 2500 N, stepwise increase of 100 N every 100 cycles, 0.5 mm/s) and a load to failure sequence (max. load 5000 N, 0.5 mm/s). Interfragmentary movement was detected via a 3-D optical measurement system. Boehler angle was measured after osteosynthesis and after failure occurred. RESULTS No significant difference regarding load to failure, stiffness, Boehler angle, or interfragmentary motion was found between the different fixation systems. A significant difference was found with the dynamic failure testing sequence where 87.5% of the Calcanail implants failed in contrast to 14% of the C-Nail group (P < .01) and 66% of the Rimbus plate. The highest load to failure was observed for the C-Nail. Boehler angle showed physiologic range with all implants before and after the biomechanical tests. CONCLUSION Both minimally invasive interlocking nail systems displayed a high primary stability that was not inferior to an interlocking plate. CLINICAL RELEVANCE Based on our results, both interlocking nails appear to represent a viable option for treating displaced intra-articular calcaneal fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه مدت زمان جوش خوردن در شکستگی های تنه استخوان ران با استفاده از دو روش پیچ و پلاک و میله داخل استخوانی فیکس شونده

Introduction & Objective: Jaundice is the most clinical finding in the neonatal period. Prolonged indirect fractures of the shaft of the femur are among the most common fractures encountered in orthopedic practice. Since the femur is the largest bone of the body and one of the principal loads bearing bone in the lower extremity, fractures can cause prolonged morbidity and extensive disability u...

متن کامل

Antegrade interlocking nailing versus dynamic compression plating for humeral shaft fractures.

PURPOSE To compare antegrade interlocking nailing with dynamic compression plating for humeral shaft fractures in terms of functional outcomes, union and complication rates. METHODS 34 men and 22 women aged >18 years with fresh humeral shaft fractures (up to grade IIIa) with or without neurological deficits underwent either antegrade interlocking nailing (n=31) or dynamic compression plating ...

متن کامل

Management of tibial non-:union: using reamed interlocking intra-medullary nailing

 Abstract  Background: Reamed interlocking intramedullary nailing of the tibia is a procedure  for the treatment of a non-infected tibial non:::union:::. The purpose of this clinical  study was to evaluate the outcome of this method as a treatment of tibial non:::union:::.  Methods: Twenty-nine patients with non:::union::: after initial therapy for tibial fracture  were retrospectively assessed...

متن کامل

A comparative study of intramedullary interlocking nailing and minimally invasive plate osteosynthesis in extra articular distal tibial fractures

BACKGROUND Extraarticular distal tibial fractures are among the most challenging fractures encountered by an orthopedician for treatment because of its subcutaneous location, poor blood supply and decreased muscular cover anteriorly, complications such as delayed union, nonunion, wound infection, and wound dehiscence are often seen as a great challenge to the surgeon. Minimally invasive plate o...

متن کامل

Letter to the Editor: Immediate interlocking nailing versus external fixation followed by delayed interlocking nailing for Gustilo type IIIB open tibial fractures.

There are several definitions for bony nonunion. We use the one that defines it as no clinical, radiographic, or scintigraphic evidence of healing 12 months after injury and by the need for secondary surgery. Delayed union is defined as the completion of union Letter to the Editor Immediate interlocking nailing versus external fixation followed by delayed interlocking nailing for Gustilo type I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Foot & ankle international

دوره 37 8  شماره 

صفحات  -

تاریخ انتشار 2016