Multi-turn transmit coil to increase b1 efficiency in current source amplification.

نویسندگان

  • N Gudino
  • M A Griswold
چکیده

PURPOSE A multi-turn transmit surface coil design was presented to improve B1 efficiency when used with current source amplification. METHODS Three different coil designs driven by an on-coil current-mode class-D amplifier with current envelope feedback were tested on the benchtop and through imaging in a 1.5 T scanner. Case temperature of the power field-effect transistor at the amplifier output stage was measured to evaluate heat dissipation for the different current levels and coil configurations. In addition, a lower power rated device was tested to exploit the potential gain in B1 obtained with the multi-turn coil. RESULTS As shown both on the benchtop and in a 1.5 T scanner, B1 was increased by almost 3-fold without increasing heat dissipation on the power device at the amplifier's output using a multi-turn surface coil. Similar gain was obtained when connecting a lower power rated field-effect transistor to the multi-turn coil. CONCLUSION In addition to reduce heat dissipation per B1 in the device, higher B1 per current efficiency allows the use of field-effect transistors with lower current ratings and lower port capacitances, which could improve the overall performance of the on-coil current source transmit system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

32 Channel Coil Array for Parallel RF Transmission

Introduction: As part of a study that investigates a substantially distributed multi-channel parallel transmit approach, head-size 32-element transmit/receive arrays were developed. The specific goal of the coil development is to facilitate reduction of RF power dissipation in the imaged object / the coil structure, and to facilitate B1 shimming / accelerated parallel excitation for an arbitrar...

متن کامل

Considerations for using linear combinations of array elements in B1 mapping

Introduction: Accurate B1 mapping of transmit coil arrays is vital for parallel transmission MRI. Current mapping methods accommodate a limited range of B1 amplitude, but can be adapted for use with coil arrays by mapping B1 fields from linear combinations of coils and solving for individual elements [1,2]. Existing formulations can be represented by an encoding matrix A, with Ai,j = 1 for i≠j,...

متن کامل

Transmit Arrays and Circuitry

For body dimensions at 3T and head dimensions at 7T and above the RF wavelength in dielectric tissue is comparable or smaller than the dimensions of the human anatomy. This in turn leads to RF phase related traveling time differences, prominent wave behavior and the potential for a significant difference between transmit B1 + and receive B1 fields [5-10]. It is possible to correct some of the r...

متن کامل

Transmit Power Optimization for Multimode Coil

Introduction: In previous work, we introduced the concept of the multimode coil [1]. The multimode coil consists of a tracking coil connected in series with a multi-turn imaging coil and simultaneously performs the functions of active tip tracking, imaging and inductively coupled wireless marker. The tracking and imaging coils have conflicting design requirements. While the region of sensitivit...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 69 4  شماره 

صفحات  -

تاریخ انتشار 2013