Using Simulations for Evaluation of Measurements on Adsl2+ Lines

نویسندگان

  • Jiří VODRÁŽKA
  • Jaromír HRAD
چکیده

The ADSL2+ lines are gradually replacing the first generation of ADSL in homes and small offices connecting to the Internet. Since there is a need to estimate the transmission speed, we have used MATLAB Web Server to design a simulator of xDSL lines that is available at our web pages. This paper compares simulations with measurement results and proposes a methodology for evaluation of measurements based on the suggestions from Slovak Telecom in connection with the practical introduction of ADSL2+ technology in 2006. The original analogue telephone lines use xDSL digital systems to a lesser or greater extent. Let us focus on the trend in the metallic access networks field and the potential possibilities for further development. Apart from the evolution of ADSL (Asymmetric Digital Subscriber Line) standards the transfer methods for the very high speed VDSL (Very-high-speed Digital Subscriber Line) are being optimized. An ADSL line transmits digital signals at various transfer speeds in opposing directions of transfer. For the connection of larger companies, especially those, which operate their own application and web servers, ADSL connection is not suitable although the SHDSL (Single-pair High-bit-rate Digital Subscriber Line) connection can be used. Allocation of bands for transfer directions downstream and upstream and also the total width of the band is dependent on the ADSL variant given by the ITU-T standard. According to the recommendation of the ITU-T G.992.1 today’s systems use a frequency band of up to 1.104 MHz. The lower part of the spectrum is of course used for telephone channels and for this reason it counts on the coexistence of ADSL in one conduit with the original analogue telephone connection (ADSL/POTS), which is preserved thanks to separation filters (adapter, splitter). Apart from this, ADSL can also coexist with the basic ISDN-BA connection (ADSL/ISDN).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fault Location on Compensated Transmission Lines without Current Measurement

This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...

متن کامل

Evaluation of AAA and XVMC Algorithms for Dose Calculation in Lung Equivalent Heterogeneity in Photon Fields: A Comparison of Calculated Results with Measurements

Aims: The aims of the present work are (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 MV small photon fields in a medium encompassing heterogeneity and (2) to compare them with measured results obtained from gafchromic film EBT2.Materials and Methods: Authors employed kailwood (Pinus Wallichiana) to mimic lung. Briefly, seven Kailwood plates, each measuring 25x...

متن کامل

High-speed Wireline Communication Systems

This report is a literature survey on multicarrier wireline communication systems, focusing primarily on the recent enhancements to the physical layer in Discrete Multitone (DMT) Modulation systems. We investigate methods used to improve the data rate versus reach performance of DMT systems proposed in the G.992.3 Asymmetric Digital Subscriber Lines-2 (ADSL2) and G.992.5 ADSL2+ standards. We al...

متن کامل

Energy-saving by low-power modes in ADSL2

The large number of broadband users and its forecast growth has recently triggered research on energy-efficiency in digital subscriber lines (DSLs). A promising technique are low-power modes (LPMs) as standardized in asymmetric DSL 2 (ADSL2) which let the DSL connection operate in downstream direction with reduced transmit rate and power. We study the problem of optimizing the LPM rate-level fo...

متن کامل

اندازه گیری کمی و کیفی استیرن در مجتمع پتروشیمی تبریز

  Background and aims   Beside the vast usages of styrene in different industries, this compound can be considered as an important organic air pollutant. Styrene, in one hand, can adversely affect on workers and on the other hands can cause air pollution in the environment. In this study, Tabriz Petrochemical Complex was selected for evaluation of styrene.   Methods   Measurements were performe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006