Bedside screening for fistula stenosis should be tailored to the site of the arteriovenous anastomosis.

نویسندگان

  • Nicola Tessitore
  • Valeria Bedogna
  • Giovanni Lipari
  • Edoardo Melilli
  • William Mantovani
  • Elda Baggio
  • Antonio Lupo
  • Giancarlo Mansueto
  • Albino Poli
چکیده

BACKGROUND AND OBJECTIVES Given different sites of stenosis and access blood flow rates (Qa), the criteria for diagnosing fistula stenosis might vary according to anastomotic site. To test this, we analyzed the database of a prospective blinded study seeking an optimal bedside screening program for fistula stenosis. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Several methods used during dialysis (physical examination [PE], dynamic and derived static venous pressure [VAPR], dialysis blood pump flow/arterial pressure ratio, and Qa measurement) to diagnose angiographically-proven >50% stenosis were assessed in an unselected population of hemodialysis patients with mature fistulae (43 at the wrist [distal fistulae], 76 at mid-forearm or the elbow [proximal fistulae]). RESULTS Prevalence of inflow stenosis was uninfluenced by anastomotic site, whereas outflow stenoses were more prevalent in proximal fistulae. The best test for inflow stenosis was Qa <650 ml/min in distal fistulae and a combination of a positive PE and Qa <900 ml/m in proximal fistulae. In proximal fistulae, PE and VAPR >0.5 were both equally highly diagnostic of outflow stenosis. Tailoring choice of test to site of the anastomosis may also contain the screening-associated workload, by reducing the need to perform PE and measure VAPR, compared with a screening approach regardless of the access location. CONCLUSIONS Our study shows that an effective bedside screening program with ≥85% accuracy for fistula stenosis can be tailored to the site of the anastomosis, Qa being the tool of choice for the wrist, and PE alone or combined with Qa and VAPR measurements for more proximally-located accesses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subclavian artery-esophageal fistula after placement of a self-expanding metal stent in a patient with esophagogastric anastomosis stenosis

Background: There have been reports on stent-related vascular erosions about patients with benign or malignant stenosis of the esophagus who received endoscopic stent insertion for palliative intention for oral intake. Case presentation: A 61-year-old woman with esophageal cancer located in the middle part of esophagus was treated with esophagectomy. Two years following the surgery, malignan...

متن کامل

Spinal dural arteriovenous fistula : a case report

Background: Spinal dural AVF is the most common type of spinal vascular malformation. However, presenting symptoms differ according to site of spinal involvement. This study described a case of arteriovenous malformation with paraparesis and incontinence. Case Presentation: Diagnosis of patient was confirmed by clinical and imaging examination using magnetic resonance image and ruling out ot...

متن کامل

پیش‌بینی شکست زودرس فیستولهای شریانی- وریدی بر مبنای معاینه در خاتمه جراحی

Background: For patients requiring chronic hemodialysis, the preferred site for vascular access is an autogenous arteriovenous fistula. Although a properly formed fistula is advantageous because it is less susceptible than other types of vascular accesses to infection and clot formation and can last longer than any other types of vascular access, AV fistula has a high rate of early failure that...

متن کامل

Congenital Esophageal Stenosis Associated with Esophageal Atresia and Gasless Abdomen

SUMMARY A radiologically gasless abdomen in a neonate with EA is usually regarded as being pathognomonic of an absence of distal T.E.F. It has been estimated that up to 1.5% of patient with a distal fistula may have a radiologically gasless abdomens as a manifestation of a very small fistula plugged with mucus. In this case a contrast study via the gastrostomy demonstrated a fistula between th...

متن کامل

Pulmonary arteriovenous fistula with bilharzial pulmonary hypertension.

Congenital pulmonary arteriovenous fistulae, provided that they are not present in very large numbers, are best managed surgically, and there is no effective alternative management. Where pulmonary arteriovenous fistulae develop as a consequence of pulmonary hypertension it is rational to resect the fistulae if the cause of pulmonary hypertension - for example, mitral stenosis - is correctable....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical journal of the American Society of Nephrology : CJASN

دوره 6 5  شماره 

صفحات  -

تاریخ انتشار 2011