Polyurethane elastomer: a new material for the visualization of cadaveric blood vessels.
نویسندگان
چکیده
A multitude of various materials are available for the visualization of cadaveric vessels, ranging from natural materials like gelatin and latex to synthetic materials like silicone rubber or acrylates. To achieve a detailed overview of the vascular architecture in microvascular studies in experimental flap surgery, the injected material should have low viscosity to assure perfusion of even the smallest vessels. In addition, the material ideally should have either no or only minimal shrinkage, and should harden within a reasonable time, but retain sufficient elasticity and resistance to withstand tearing off the delicate vessels during subsequent dissection or casting. Because none of the available injection materials adequately combines these attributes, we evaluated the polyurethane elastomer "PU4ii" in latissimus dorsi muscles as a new material for the visualization of cadaveric vessels in comparison with the frequently used silicone rubber. The dissection of vessels injected with PU4ii proved easy largely because of its exceptional hardness. Even if not visible before dissection, the completely perfused vessels were easily palpated in the surrounding fat or muscle tissue of the microsurgical latissimus dorsi model. Despite the significantly higher hardness of PU4ii over silicone rubber (98 Sh-A vs. 12 Sh-A), PU4ii proved enough elasticity (20-25 N/mm(2) E modulus) and a high tear resistance (64-68 N/mm vs. 15 N/mm) preventing breakage during dissection even within the smallest vessels. In contrast to silicone rubber (and latex or gelatin), the high corrosion resistance and form stability of PU4ii also allowed building of casts for qualitative examination by scanning electron microscopy and quantitative analysis of the vessel density using micro-computed tomography with accurate 3D representation. In this study we show that PU4ii has physical characteristics that make it a multi-purpose material that allows at the same breath an excellent gross visualization of the architecture of cadaveric blood vessels as well as a detailed evaluation of casts by modern microscopic and or radiologic tools. Thus, the new polyurethane elastomer PU4ii is in many respects superior to the widely used silicone rubber and can be strongly recommended as a visualization material for a comprehensive evaluation of cadaveric blood vessels in microsurgery.
منابع مشابه
تهیه الاستومر پلی یورتانی با استفاده از HTPB سنتز شده به روش پلیمریزاسیون رادیکالی زنده با واسطه نایتروکساید: سنتز، (علمی-پژوهشی)
In order to increasing of hydroxy functionality of HTPB an in-situ nitroxide mediated polymerization (NMP) of 1,3-butadiene was carried out in presence of TEPA as a polyfunctional nitroxide precursor. The multi-modal molar mass distribution of the product was elucidated by reductive hydrolyzation of the oligomeric product. The new polyfunctional hydroxyl-terminated polybutadiene (PFHTPB) was c...
متن کاملInvestigation of the Properties of Polyurethane Elastomer Based on Synthesis and Characterization of PTHF-GAP-PTHF Triblock Copolymer
Binder has a key role in the performance of composite propellants. The binders are classified into two neutral and high-energy categories. GAP is one of the most important energetic binders, but it has poor mechanical and thermal properties. The goal of this investigation is to improve the properties of GAP by copolymerizing it with polytetrahydrofuran. New energy triblock copolymer was synthes...
متن کاملThe Fracture Energy and Some Mechanical Properties of a Polyurethane Elastomer
The energy required to form a unit of new surface in the fracture of a polyurethane elastomer is determined. The rate sensitivity of the material has been reduced by swelling it in toluene. This paper primarily describes the experimetal work of measuring the lower limit of the fracture energy. With this value and the creep compliance as a basis, the rate dependence of fracture energy for the un...
متن کاملAn artificial blood vessel fabricated by 3D printing for pharmaceutical application
Objective(s): Cardiovascular diseases (CVDs) are the leading cause of mortality in the elderly. A common medical procedure for the treatment of CVDs is the replacement of the blocked or narrowed arteries, which is currently the optimal vascular transplant associated with autograft transplantation. In general, the saphenous veins and radial arteries in the mammary gland are considered to be the ...
متن کاملI-45: Color Doppler Sonography of Endometrium in Infertility Patients
Background Endometrial receptivity is one of parameters which determine the reproductive outcome in in vitro fertilization programs. A good blood supply towards the endometrium is usually considered to be an essential requirement for implantation. Blood vessels of the endometrium can be detected by transvaginal color and pulse Doppler sonography. Color Doppler assessment permits better visualiz...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical anatomy
دوره 20 4 شماره
صفحات -
تاریخ انتشار 2007