Flecainide overdose – support using an intra-aortic balloon pump

نویسندگان

  • Jonathan Timperley
  • Andrew RJ Mitchell
  • Peter D Brown
  • Nicholas EJ West
چکیده

BACKGROUND Flecainide is an antiarrhythmic agent which is being used increasingly for the management of super-ventricular arrhythmias. Overdose with flecainide is frequently fatal with mortality reported as high as 22% due to arrhythmias, myocardial depression and conduction defects leading to electro-mechanical dissociation and asytole. Supportive measures are often required during the case and previously have included inotropes, extracorporeal membrane oxygenation and cardiopulmonary bypass. CASE PRESENTATION A 47 year old lady presented to the emergency department with a four hour history of severe central chest pain. Her ECG showed atrial fibrillation and broad QRS complexes with a sine wave appearance. She had a past history of paroxysmal atrial fibrillation and significant psychiatric history. Following thrombolysis for a presumed myocardial infarction she developed cardiogenic shock with severely impaired left ventricular function. An intra-aortic balloon pump was inserted and coronary angiography demonstrated normal coronary arteries. With inotropic support she improved over 48 hours, with both her QRS duration and left ventricular function returning to normal. Biochemical testing following her discharge demonstrated significantly elevated levels of flecainide. CONCLUSION The use of an intra-aortic balloon pump is a useful supportive measure during the acute phase of flecainide overdose associated with severe myocardial depression.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

Flecainide-Induced Torsade de Pointes Successfully Treated with Intensive Pharmacological Therapy

Flecainide is a class IC anti-arrhythmic drug that acts by blocking the fast inward sodium channels during phase 0 of action potential. It is used to treat both supraventricular and ventricular arrhythmias. However, flecainide is also a pro-arrhythmic agent, and overdose may cause nausea, vomiting, hypotension, bradycardia, varying degrees of atrioventricular block, tachyarrhythmias (such as to...

متن کامل

Intra aortic balloon pump: literature review of risk factors related to complications of the intraaortic balloon pump

The increasing use of the intra aortic balloon pump is attributed to the relatively easy percutaneous insertion and the low threshold of use over the past few years, especially in elderly patients with multi-vessel diseases and an affected ejection fraction.Unfortunately, the clinical assessment of the complications associated to the use of this supporting device, underestimates the frequency o...

متن کامل

Intra-aortic balloon pump in patients with cardiogenic shock complicating myocardial infarction: a systematic review and meta-analysis of randomized trials (protocol)

BACKGROUND Cardiogenic shock is the leading cause of death in patients with acute myocardial infarction. Despite significant advancements in health technology and research, hospital mortality approaches 50%. The intra-aortic balloon pump is a mechanical hemodynamic assist device that has been used for over 40 years in the management of patients with cardiogenic shock. A recent randomized trial ...

متن کامل

A randomized comparison of intra-aortic balloon pumping after primary coronary angioplasty in high risk patients with acute myocardial infarction.

AIMS Intra-aortic balloon pumping reduces afterload and may be effective in improving reperfusion in high risk infarct patients treated with primary angioplasty. METHODS High risk infarct patients referred from other centres for primary PTCA were randomized to treatment with or without an intra-aortic balloon pump. The primary end-point consisted of the combination of death, non-fatal reinfar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Emergency Medicine

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2005