Radiochromic film dosimetry in water phantoms.

نویسندگان

  • M J Butson
  • T Cheung
  • P K Yu
چکیده

Radiochromic film is investigated for use in dosimetry in water phantoms as opposed to solid phantoms. Investigations are performed to measure the penetration rates of water into radiochromic film and to assess the effects on optical density that this penetration causes. The effects of film orientation during irradiation in water are also tested. Results show that only a small penetration rate is seen from water into the film which only affects the outer areas of the film, with penetration being less than 0.5 mm per hour. The optical density measurements of the film at 660 nm remain unchanged in the unaffected regions of the radiochromic film. Minimal effects are seen due to beam orientation in a water phantom as opposed to solid water phantoms in which an overestimation in dose is normally seen for parallel irradiation. Radiochromic film seems to be an adequate detector for dosimetry in a water phantom where high spatial resolution is needed and angle of beam incidence at the point of interest is important.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation

Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...

متن کامل

Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom

We validated 3D radiochromic film dosimetry for volumetric modulated arc therapy (VMAT) using a newly developed spiral water phantom. The phantom consists of a main body and an insert box, each of which has an acrylic wall thickness of 3 mm and is filled with water. The insert box includes a spiral film box used for dose-distribution measurement, and a film holder for positioning a radiochromic...

متن کامل

Use of new radiochromic devices for peripheral dose measurement: potential in-vivo dosimetry application

The authors have studied the feasibility of using three new high-sensitivity radiochromic devices in measuring the doses to peripheral points outside the primary megavoltage photon beams. The three devices were GAFCHROMIC® EBT film, prototype Low Dose (LD) Film, and prototype LD Card. The authors performed point dosimetry using these three devices in water-equivalent solid phantoms at x = 3,5,8...

متن کامل

Dosimetry intercomparison using a 35-keV X-ray synchrotron beam.

The purpose of this study was to compare dose measurements using ion chamber and radiochromic film dosimetry for a 35-keV synchrotron beam useful for Auger electron therapy. A 1.3-GeV electron beam, transported through a 3-pole superconducting wiggler magnet, produced a polychromatic photon beam from which a 35-keV beam (3.3 mm Al HVL) was selected using a monochromator. A 2.8 cm x 2.5 cm field...

متن کامل

Skin Dosimetry in Radiotherapy of Breast Cancer: a Comparison between EBT and EBT3 Radiochromic Films

Objective: Radiochromic EBT3 film is a later generation of radiochromic films. The aim of this study is to compare EBT and EBT3 radiochromic films in radiotherapy fields of breast cancer.Methods: A RANDO phantom was irradiated by a 6 MV Siemens Primus linac with medial and lateral fields of radiotherapy of breast cancer. Dosimetry was performed in various points in the fields using EBT and EBT3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 46 1  شماره 

صفحات  -

تاریخ انتشار 2001