Non-Contrast Enhanced MR Angiography (NCE-MRA) of the Calf: A Direct Comparison between Flow-Sensitive Dephasing (FSD) Prepared Steady-State Free Precession (SSFP) and Quiescent-Interval Single-Shot (QISS) in Patients with Diabetes

نویسندگان

  • Na Zhang
  • Liqiu Zou
  • Yi Huang
  • Dexiang Liu
  • Yukuan Tang
  • Zhaoyang Fan
  • Hanwei Chen
  • Xin Liu
  • Xiaoming Yang
چکیده

OBJECTIVES To compare the image quality and diagnostic performance of two non-contrast enhanced MR angiography (NCE-MRA) techniques using flow-sensitive dephasing (FSD) prepared steady-state free precession (SSFP) and quiescent-interval single-shot (QISS) for the calf arteries in patients with diabetes. MATERIALS AND METHODS Twenty six patients underwent the two NCE-MRA techniques followed by contrast-enhanced MRA (CE-MRA) of lower extremity on a 1.5T MR system. Image quality scores, arterial stenosis scores, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, and diagnostic accuracy for detecting more than 50% arterial stenosis were evaluated and statistically compared using CE-MRA as the reference standard. RESULTS All examinations were performed successfully. Of the total 153 calf arterial segments obtained in the 26 patients, FSD and QISS showed no significant difference in the number of diagnostic arterial segments (151 [98%] vs. 147 [96%], respectively, P>0.05). The image quality of FSD was higher than that of QISS in the peroneal artery and posterior tibial artery (P<0.05), but no significant difference in the anterior tibial artery (P>0.05). SNR and CNR of FSD were higher than those of QISS (P<0.01), while FSD showed comparable vessel sharpness compared with QISS (P>0.05). The time efficiency of SNR and CNR between FSD and QISS showed no significant difference when taking into account the times for FSD-related scout scans. There was no difference in sensitivity (95% vs. 93%, P>0.05) and negative predictive value (98% vs. 97%, P>0.05) between FSD and QISS for detecting stenosis greater than 50%. However, FSD showed higher specificities (99% vs. 92%, P<0.05) and diagnostic accuracy (98% vs. 92%, P<0.05) compared to QISS. CONCLUSION Both FSD and QISS had similar high sensitivity and negative predictive value for detecting calf arteries with over 50% stenosis, but FSD showed slightly higher diagnostic specificity and better depiction of arterial lesions due to its isotropic submillimeter spatial resolution. QISS, being an easier to use and less time-consuming technique, could be a method of choice for rapid screening of arterial disease of the lower extremity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Image Quality and Stenosis Assessment of Non-Contrast-Enhanced 3-T Magnetic Resonance Angiography in Patients with Peripheral Artery Disease Compared with Contrast-Enhanced Magnetic Resonance Angiography and Digital Subtraction Angiography

PURPOSE To evaluate the diagnostic performance of flow-sensitive dephasing (FSD)-prepared steady-state free precession (SSFP) magnetic resonance angiography (MRA) at 3 T for imaging infragenual arteries relative to contrast-enhanced MRA (CE-MRA) and digital subtraction angiography (DSA). MATERIALS AND METHODS A series of 16 consecutive patients with peripheral arterial disease (PAD) underwent...

متن کامل

Quiescent Interval Single Shot MR Angiography

Introduction Given the frequency of renal functional impairment in patients with peripheral vascular disease (PVD) and concerns about nephrogenic systemic fibrosis, there is growing interest in unenhanced MRA (1,2). While promising, existing unenhanced MRA methods suffer from limitations that preclude robust clinical application for PVD. An ideal unenhanced method should be fast, easy to use, a...

متن کامل

Non-contrast enhanced MR angiography: physical principles.

Noncontrast-enhanced magnetic resonance angiography (NCE-MRA) methods have been demonstrated in anatomies throughout the body. Previously established NCE-MRA techniques suffered from long scan times or low sensitivity. Advances in hardware and software have made NCE-MRA scan times clinically feasible. Recent concerns over the safety of gadolinium-based contrast material combined with the expens...

متن کامل

Breath-hold imaging of the coronary arteries using quiescent-interval slice-selective (qiss) magnetic resonance angiography - pilot study at 1.5 tesla and 3 tesla

BACKGROUND Coronary magnetic resonance angiography (MRA) is usually obtained with a free-breathing navigator-gated 3D acquisition. Our aim was to develop an alternative breath-hold approach that would allow the coronary arteries to be evaluated in a much shorter time and without risk of degradation by respiratory motion artifacts. For this purpose, we implemented a breath-hold, non-contrast-enh...

متن کامل

3D Non-Contrast-Enhanced MRA Using Flow-Sensitive Dephasing (FSD) Prepared Balanced SSFP: Identification of the Optimal First-Order Gradient Moment

Introduction: A non-gadolinium-enhanced MRA technique using ECG-triggered 3D balanced SSFP with flow-sensitive dephasing (FSD) preparation has recently been developed and validated in the distal lower extremities of healthy volunteers [1]. The FSD’s first-order gradient moment, m1, is shown to be the most important parameter to determine angiographic quality. A suboptimal m1 may result in venou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015